Alcatel-Lucent 6850-48 参考指南
AAA Commands
OmniSwitch CLI Reference Guide
September 2009
page 58-59
user password-history
Configures the maximum number of old passwords to retain in the password history.
user password-history number
Syntax Definitions
number
The maximum number of old passwords to retain.
The range is 0 to 24.
The range is 0 to 24.
Defaults
Platforms Supported
OmniSwitch 6400, 6850, 6855, 9000, 9000E
Usage Guidelines
• Specify 0 with this command to disable the password history function.
• The user is prevented from specifying any passwords that are recorded in the password history and fall
within the range configured through this command.
• The password history value is specified as part of a global password policy that is applied to all pass-
words when they are created or modified.
Examples
-> user password-history 2
-> user password-history 0
Release History
Release 6.3.1; command was introduced.
Related Commands
MIB Objects
aaaAsaConfig
aaaAsaPasswordHistory
parameter
default
number
4
Displays the global password policy configuration for the switch.