Alcatel-Lucent 6850-48 硬件手册

下载
页码 188
Managing OmniSwitch 6850 Series Stacks
Roles Within the Stack
OmniSwitch 6850 Series Hardware Users Guide
September 2009
page 4-11
Idle Module Role
Switches that are not assigned either the primary or secondary role in a stack are, by default, assigned the 
role of idle modules. These idle modules operate similarly to Network Interface (NI) modules in a chassis-
based switch such as the OmniSwitch 9700/9800. It is the job of idle modules to send and receive 
10/100/1000 Ethernet traffic on their.
In the event of a management module failure within the stack, the idle module with the next lowest slot 
number in the stack will automatically assume the secondary management role. In other words, if the 
primary module in a stack goes down for any reason and the secondary takes over the primary manage-
ment role, the switch must now assign a new secondary module. The idle element with the next lowest slot 
number assumes this new responsibility until the situation is corrected and all elements in the stack are 
reloaded.
Note. Primary and secondary management modules also send and receive 10/100/1000 traffic on their 
Ethernet. The primary management module is like an NI module with the added task of overall stack 
management; the secondary management module is like an NI with the added responsibility of backing up 
the primary module in the event of a primary module failure. In other words, all modules in the virtual 
chassis can send and receive user data, regardless of their roles.
For more information on dynamic assignment of idle modules in a stack, refer to the diagram below:
Secondary Management Module Selection Using Saved Slot Information
Four OmniSwitch 6850 Series switches are stacked; all switches are 
connected via stacking cables. The stack is booted. 
Primary
Secondary
The primary and secondary management modules are dynamically 
assigned using any of the methods outlined on pages 
 through 
2
1
Idle 
Idle
Primary
Secondary
The system software automatically assigns the remaining elements 
in the stack the idle module role. These modules act as Network 
Interface (NI) modules, sending and receiving 10/100/1000 
Ethernet traffic on their.
In the event of a primary-to-secondary failover, the idle module 
with the next-lowest slot number in the stack will assume the 
secondary—or backup—management role.
3