Küppersbusch kgc 907.2e 安装指导

下载
页码 12
When assembling the connecting box remember that it must be at least
300 mm from the floor, as shown in the drawing.
The connecting box must not come into contact with any hot appliance
parts.
If there is no built-in oven below the hob, the connecting box can also
be fastend to the furniture below the hob.
The connecting box must not be used as a voltage distributor for other
appliances.
The appliance is connected to the mains at the connecting box as
shown in the wiring diagram. The connection may only be made in the
connector box.
The connector box must not be removed.
The fitted connection cable must be replaced by the Küppersbusch Cu-
stomer Service if it becomes damaged. 
The green-yellow earth conductor must be longer than the other wires.
Connection diagram:
Caution:
Incorrect connection results in the total destruction of the power electronics.
Electrical connection
Permanent connection by means of an oven
connection socket.
Connection diagram
is depicted on the underside of the applian-
ce, suitable for the various types of mains.
Connection data
Permanent connection 400 V 3 N 
 50 Hz
(AC 230 V in UK)
Voltage of heating element: 230 V
Total connection output: 10,4 kW
400 V 3 N 
 safety current 16 A
400 V 2 N 
 safety current 20 A
230 V 1 N 
 safety current 25 A
230 V 3 
 safety current 16 A
Connection cable
Use H 05 RR-F or H 07 RN-F.
Length of cable as necessary.
Single-phase connection 230 V phase against neutral conductor
Three-phase connection 400 V system with 230 V phase against neu-
tral conductor
Three-phase system 230 V phase against phase
Supply line from
cooker junktion box
The conductor colours may be different. The connection diagram
and the terminal numbers are the decisive factors.
base
Cable to
the hob
20