Rotel RSP-1069 补充手册
RSP 1069 HEX
Command Expected
Command
FE 03 A2 33 5F 37
Zone 3 Volume 95
Zone 3 Volume 95
FE 03 A2 33 60 38
Zone 3 Volume Max
Zone 3 Volume Max
Table 12: Commands Sent with exceptions or modifications required
RSP 1069 HEX
Command Expected
Command
FE 03 A2 33 25 FD
FE 03 A2 33 25 FD 00
Zone 3 Volume 37
FE 03 A2 33 26 FE
FE 03 A2 33 26 FD 01
Zone 3 Volume 38
The table above list commands with exceptions. To keep the RSP 1069 from encountering the
start byte FE in any position other than as the start byte, any occurrence of the bytes FE or FD in
the command string must be converted to either FD 00 (for FD) or FD 01 (for FE). This will allow
the string to pass while masking any occurrence of the byte FE except as the start byte.
Table 13: Type 34 Zone 4 Volume Direct Command List
RSP 1069 HEX
Command
Command Description
FE 03 A2 34 00 D9
Zone 4 Volume Min
Zone 4 Volume Min
FE 03 A2 34 01 DA
Zone 4 Volume 1
Zone 4 Volume 1
FE 03 A2 34 02 DB
Zone 4 Volume 2
Zone 4 Volume 2
FE 03 A2 34 03 DC
Zone 4 Volume 3
Zone 4 Volume 3
FE 03 A2 34 04 DD
Zone 4 Volume 4
Zone 4 Volume 4
FE 03 A2 34 05 DE
Zone 4 Volume 5
Zone 4 Volume 5
FE 03 A2 34 06 DF
Zone 4 Volume 6
Zone 4 Volume 6
FE 03 A2 34 07 E0
Zone 4 Volume 7
Zone 4 Volume 7
FE 03 A2 34 08 E1
Zone 4 Volume 8
Zone 4 Volume 8
FE 03 A2 34 09 E2
Zone 4 Volume 9
Zone 4 Volume 9
FE 03 A2 34 0A E3
Zone 4 Volume 10
Zone 4 Volume 10
FE 03 A2 34 0B E4
Zone 4 Volume 11
Zone 4 Volume 11
FE 03 A2 34 0C E5
Zone 4 Volume 12
Zone 4 Volume 12
FE 03 A2 34 0D E6
Zone 4 Volume 13
Zone 4 Volume 13
FE 03 A2 34 0E E7
Zone 4 Volume 14
Zone 4 Volume 14
FE 03 A2 34 0F E8
Zone 4 Volume 15
Zone 4 Volume 15
FE 03 A2 34 10 E9
Zone 4 Volume 16
Zone 4 Volume 16
FE 03 A2 34 20 F9
Zone 4 Volume 32
Zone 4 Volume 32
FE 03 A2 34 30 09
Zone 4 Volume 48
Zone 4 Volume 48
FE 03 A2 34 40 19
Zone 4 Volume 64
Zone 4 Volume 64
FE 03 A2 34 50 29
Zone 4 Volume 80
Zone 4 Volume 80
FE 03 A2 34 50 38
Zone 4 Volume 95
Zone 4 Volume 95
FE 03 A2 34 50 39
Zone 4 Volume Max
Zone 4 Volume Max