Traulsen uc1lt 规格指南

下载
页码 2
Project
Quantity
Item #
Model Specified:
CSI Section 11400
TRAULSEN
4401 BLUE MOUND RD.
FT. WORTH, TX 76106
PHONE 1 (800) 825-8220
FAX-MKTG. 1 (817) 624-4302
Website: www.traulsen.com
SECTION
2-2
NOTE: When ordering please specify: Voltage, Hinging, Options and any additional
warranties.
Continued product development may necessitate specification changes without notice.
Part No. TR35775 (revised 1/07)
Construction, Hardware and Insulation
Cabinet exterior front, one-piece louver assembly and doors are constructed of 20
gauge stainless steel with #4 finish. Cabinet interior and door liners are constructed
of stainless steel. The exterior cabinet sub-top, sides, back and bottom are
constructed of heavy gauge aluminized steel. A set of adjustable 6" high stainless
steel legs are included.
Doors are field reversible, and equipped with a gasket protecting metal door pan and
guaranteed for life cam-lift, gravity action, self-closing metal, glide hinges with stay
open feature at 120 degrees. A full height vertical handle is recessed in the door,
eliminating protrusion into aisleways.
Easily removable for cleaning, vinyl magnetic door gasket assures tight door seal.
Anti condensate heaters are located behind each door opening.
Both the cabinet and door(s) are insulated with an average of 2" thick high density,
non-CFC, foamed in place polyurethane.
Interior
Standard interior arrangements include two (2) chrome plated wire shelves per door,
mounted on shelf pins. Recommended load limit per shelf should not exceed 225
lbs. Optional tray slides may be purchased in combination with, or in lieu of these.
Both standard and optional interior arrangements are completely installed at the
factory.
Refrigeration System
The self-contained, balanced refrigeration system using R-404A refrigerant is
conveniently located within a removable power pack.  It features a hot gas
evaporator defrost, thermostatic expansion valve, air-cooled hermetic compressor,
plenum effect blower coil, large, high humidity evaporator coil located outside the
food zone and an electric condensate evaporator.  A 9' cord and plug is provided.
Standard operating temperature is 0 to -5°F.
Controller
The easy to use water resistant  INTELA-TRAUL
®
 microprocessor control system is
supplied standard. Unit is NAFEM Data Protocol communication (NDP) ready.
Optional hardware required to be NDP compliant.  Third party software required for
network connection.  It includes a 3-Digit LED Display, Fahrenheit or Celsius
Temperature Scale Display Capability, Defrost Lockouts, and an RS485 data port.
In addition it includes audio/visual alarms for: Hi/Lo Cabinet Temperature, Clean
Condenser, Evaporator Coil and Discharge Line Sensor Failures, and Power Supply
Interruption.
Warranties
Both a one year parts and labor warranty and a five year compressor warranty (self-
contained models only) are provided standard.  An optional 2
nd
 year extended parts
and labor warranty is also available. In addition the INTELA-TRAUL
®
  control is
warranted by a two year parts and labor warranty.
Specifications
NOTES
NOTE: Figures in parentheses reflect metric equivalents.
1=
For shipping weights and dimensions please refer to spec sheet 12-4.
2=
Based on a 90 degree F ambient and -15 degree F evaporator.  For information on
remote models, please refer to spec sheet 12-2.
DIMENSIONAL DATA
UC1LT
UC2LT
Net Capacity cu. ft.
8.6 (244 cu l)
18.8 (533 cu l)
Length Overall in.
42
1
2
 (108.0 cm) 69
1
2
 (176.5 cm)
Depth - Cabinet Only in.
32 (81.3 cm)
32 (81.3 cm)
Depth - with Door Open 90°
58
7
16
 (148.4 cm) 58
7
16
 (148.4 cm)
Depth - Overall in.
34
1
4
 (87.0 cm)
34
1
4
 (87.0 cm)
Height - Overall on 6" Legs in. 34 (86.4 cm)
34 (86.4 cm)
Net Weight-uncrated lbs.
1
350 (159 kg)
400 (181 kg)
Number of Shelves
2
4
Shelf Area sq. ft.
8.6 (2.6 sq. m.)
18.7 (5.7 sq. m.)
ELECTRICAL DATA
Voltage
115/60/1
115/60/1
Feed Wires with Ground
3
3
Full Load Amperes
9.3
9.3
REFRIGERATION DATA
Refrigerant
R-404A
R-404A
BTU/HR - HP
2
2700 (
1
4 HP
)
2700 (
1
4 HP
)
Elevation - UC1LT
Elevation - UC2LT
Plan - UC2LT
Plan - UC1LT
Section - All Models
NOTE: An optional stainless steel worktop is required on
full size undercounter models being used to support
equipment weighing in excess of 100 lbs. or producing
heat in excess of 140
°
F to the top surface.
Equipped With One NEMA 5-15 P Plug