Printronix l7032 参考手册
296
Chapter
3
Bar Codes
Readable Data
The optional readable data field provides a readable interpretation of the bar
code data. It can be printed above or below the bar code symbol.
code data. It can be printed above or below the bar code symbol.
Check Digit
The modulo-103 check digit is automatically calculated and inserted in the bar
code symbol. The check digit verifies accurate scanning. The start code is
included in the check digit algorithm.
code symbol. The check digit verifies accurate scanning. The start code is
included in the check digit algorithm.
UPS 11 Command Format
NOTE: See page 164 for the IBARC, command format and definitions.
Default Ratio:
(cc)
dir p u data (cc)G
Variable Ratio:
(cc)
dir p [9] [:] u [ratio] data (cc)G
(cc)
Represents the Special Function Control Code
(SFCC). Enter the specific SFCC for your VGL
configuration.
(SFCC). Enter the specific SFCC for your VGL
configuration.
dir
Represents the direction of the bar code. Enter B
for horizontal bar codes; enter C for vertical bar
codes.
for horizontal bar codes; enter C for vertical bar
codes.
p
Prints the optional readable data field. The
readable data field is printed below a horizontal bar
code or on the left-hand side of a vertical bar code.
readable data field is printed below a horizontal bar
code or on the left-hand side of a vertical bar code.
Replace
p in the bar code command with one of the
codes listed below to print the readable data field in
the corresponding font with the specified guard
band gap.
the corresponding font with the specified guard
band gap.
Table 67. Printable Data Field Fonts
Font
Gap
p code
Standard 10 cpi
3 dots
Y
OCR-A
3 dots
O
OCR-A
.1-inch
S
OCR-B
3 dots
B
OCR-B
.1-inch
T
None
N