Printronix SL4M 参考手册

下载
页码 112
RFID CONTROL Menu Items (SL5000r)
29
Overstrike Style
This menu item selects the style of the overstrike pattern.
The default is Grid.
When it is set to Grid, a grid pattern prints when it overstrikes. 
When it is set to Error Type Msg, an error message prints that 
indicates which error occurred (see Table 2).
IMPORTANT
If you are using a validator, set the RFID Overstrike Style 
different than the validator Overstrike Style (in the VALIDATOR 
menu). This will help you differentiate between an RFID error 
and a validator error.
NOTE: The 
x in the error messages represents a number code that 
identifies the area in the printer software or RFID encoder 
where the failure occurred.
Table 2. Printed Overstrike Error Messages
Error Message
Explanation
Tag R/W Err 
x
Check media
The printer software attempted to write to or read from the 
RFID tag, but the RFID encoder indicated that the tag could 
not be written to or read from.
Tag Comm Err 
x
Check cable
The printer software temporarily lost communication with the 
RFID encoder, or communication between the printer 
software and the RFID encoder was not synchronized and 
had to be forced.
Precheck Fail 
x
Check media
This failure occurs only when the Precheck Tags menu item 
is set to Enable. It indicates that the RFID tag was 
automatically failed since it did not contain the correct 
pre-programmed quality code.