Maintenance
When the lamps are replaced, the filters should also be replaced, not cleaned.
Refer to the following guide to replace the filters.
 CAUTION
Do not drop the projector on your hand or fingers while lifting the projector to 
replace the filters. Doing so could injure your hand or fingers.
 Note
The side and the rear filters can be pulled out from 
the slots located  at the bottom as shown.
1
 Gently slide the filter holders in the direction 
shown.
 Lift the filter foams from all three filter 
holders in the direction shown.  
Remove them completely from each filter 
holder and discard.
 Place a replacement foam and press down 
firmly.
4
 Replace the filter holders by pushing gently 
in the direction shown.
 Note
When  dirt  and  dust  build  up  in  the  filter,  the  air  circulation  inside  the  projector  is 
affected and the internal temperature will rise, causing the projector to stop working or 
malfunction.
Be sure the filter is inserted all the way into the slot. Leaving gaps will allow dust and 
dirt to get inside the projector again.
When you purchase a new lamp, new filters are also provided. If a filter is torn or dirty, 
please replace with new one. Continuing to use a ripped filter will allow dust and dirt to 
get inside the projector.
Never run the projector with the filters removed. It is recommended that you clean the 
Replacing the filters
Bottom
Resetting the filter time counter
After replacing the filters, the filter time counter should be reset to zero. Refer to the 
following guide:
1
 Press the MENU button on the control panel or remote to open the Main menu.
 Press the p or q button to move to the [Reset] menu and press Enter.
The [Reset] menu is displayed. 
 Select [Clear filter time] using p or q and press Enter.
A confirmation box is displayed. 
4
 Select OK using t or u and press Enter to reset the filter time to zero.