Champion eucc series 安装指导
206
Motors
Low voltage:
115 VAC
208-240 VAC,50/ 60HZ, 1 and 3 PH
High voltage:
480 VAC, 50/60HZ, 3 PH
High voltage:
575 VAC, 50/60HZ, 3 PH
(Special order only - Must have factory approval)
120VAC, 50/60HZ, 1 PH
Horsepower:
Prewash pump:
Prewash pump:
1, 2 or 3 HP
Wash pump:
3 HP
Rinse pump:
3 HP
EconoRinse pump:
1/5 HP,
(115 VAC)
Conveyor drive:
1/2 HP
Motor Wiring:
1.
Refer to the wiring diagram at right.
2.
208VAC/240VAC/3PH motors are connected per
the low voltage diagram.
the low voltage diagram.
3.
480VAC/575/3PH motors are connected per
the high voltage diagram.
the high voltage diagram.
4.
The 115 VAC econo-rinse pump motor has a
flexible power cord, (WHT, BLK, GRN wires).
flexible power cord, (WHT, BLK, GRN wires).
Troubleshooting:
Motor will not run:
1.
Check incoming 3-phase power at the
main terminal block in the control cabinet.
main terminal block in the control cabinet.
2.
Check for tripped motor overload in control cabinet.
Motor runs hot and trips motor overload:
1.
Check for proper voltage between L1-L2, L2-L3, L1-L3.
2.
Check FLA on motor leads L1, L2, L3 using amp tester.
(Motor full load amp ratings, (FLA), are stamped on motor nameplates).
Motor runs hot and trips motor starter overload:
1.
Check for proper voltage between L1-L2, L2-L3, L1-L3.
2.
Check FLA on motor leads L1, L2, L3 using amp tester. (Motor full load amp (FLA)
ratings are stamped on motor nameplate).
ratings are stamped on motor nameplate).
Basic Service ________________
Electrical Service
Basic Service • Electrical