Roland Fantom-Xa 业主指南

下载
页码 264
 
109
Editing a Sample
 
This operation raises the level of the entire sample as much as 
possible without exceeding the maximum level. In some cases, the 
volume of a phrase you resampled (p. 100) will be lower than the 
volume of the original phrase. In this case, it is a good idea to boost 
the volume by executing the Normalize operation.
 
*
You cannot execute this with more than one sample selected.
 
1.
 
Press [SAMPLE EDIT <-> LIST] to access the SAMPLE EDIT 
screen.
 
2.
 
Press [F3 (MODIFY)] to open the Sample Modify Menu 
window.
 
3.
 
Press [F2 (NORM & AMP)], and then press [F1 (NORM)].
 
fig.NORMALIZE
 
4.
 
If you want to replace the current sample with the 
normalized sample, press [F4 (OVER WRITE)] to display the 
 
 
” mark.
 
5.
 
Press [F6 (EXEC)].
 
A message will ask you for confirmation.
 
6.
 
To execute, press [F6 (EXEC)].
 
*
To cancel, press [F5 (CANCEL)].
 
This operation adjusts the volume of the entire sample. You can also 
apply an envelope (time-variant change) to the volume of the 
sample.
 
*
You cannot execute this with more than one sample selected.
 
1.
 
Press [SAMPLE EDIT <-> LIST] to access the SAMPLE EDIT 
screen.
 
2.
 
Press [F3 (MODIFY)] to open the Sample Modify Menu 
window.
 
3.
 
Press [F2 (NORM & AMP)], and then press [F2 (AMP)].
 
fig.AMP
 
4.
 
If you want to adjust the volume of the entire sample, use 
the VALUE dial or [INC] [DEC] to set the rate of volume 
boost.
 
5.
 
If you want to apply an envelope, specify points.
Press [F3 (POINT)] to display the “
 
 
” mark. Then press 
 
or 
 to select a parameter, and then use the VALUE dial 
or [INC] [DEC] to set the value.
 
6.
 
If you want to replace the current sample with the edited 
sample, press [F4 (OVER WRITE)] to display the “
 
 
” mark.
 
7.
 
Press [F6 (EXEC)].
 
A message will ask you for confirmation.
 
8.
 
To execute, press [F6 (EXEC)].
 
*
To cancel, press [F5 (CANCEL)].
 
Maximizing the Volume of a 
Sample (NORMALIZE)
 
AMP
 
Parameter
Explanation
 
Rate
Rate of volume boost
Specifies how much boost will be applied 
relative to the current volume
 
0–400%
Parameter
Explanation
 
Current Point
Currently selected point
Beginning near the start point, the points 
will be numbered 1, 2, 3, or 4.
Point 1–4
Location of the current point
Rate 1–4
Amplification ratio of the current point
Specifies how the volume of each point is to 
be boosted relative to the current value.
 
0–400%
Fantom-Xa_e.book 109 ページ 2004年10月22日 金曜日 午後2時3分