Editing a Audio Phrase (Sample)
 
5.
 
Press [F6 (EXEC)].
 
A message will ask you for confirmation.
 
6.
 
To execute, press [F6 (EXEC)].
 
*
To cancel, press [F5 (CANCEL)].
 
In some cases, the audio quality will be improved if you boost the 
high-frequency range of an imported sample. Also, the high-
frequency range of the sample may be emphasized when you use a 
sampler made by another manufacturer. In this case, you can 
minimize the change in tonal character by attenuating the high-
frequency range.
 
*
You cannot execute this with more than one sample selected.
 
1.
 
In the SAMPLE EDIT screen, press [F3 (MODIFY)] to open 
the Sample Modify Menu window.
 
2.
 
Press [F1 (TRUNC&EMPHS)], and then press [F2 (EMPHS)].
 
fig.EMPHASIS
 
3.
 
Use the VALUE dial or [INC] [DEC] to select the emphasis 
type.
PreEmphasis:
 
 Emphasizes the high-frequency range.
 
DeEmphasis:
 
 Attenuates the high-frequency range.
 
4.
 
If you want to replace the current sample with the 
emphasized sample, press [F4 (OVER WRITE)] to display 
the “
 
 
” mark.
 
5.
 
Press [F6 (EXEC)].
 
A message will ask you for confirmation.
 
6.
 
To execute, press [F6 (EXEC)].
 
*
To cancel, press [F5 (CANCEL)].
 
This operation raises the level of the entire sample as much as 
possible without exceeding the maximum level. It is a good idea to 
boost the volume by executing the Normalize operation.
 
*
You cannot execute this with more than one sample selected.
 
1.
 
In the SAMPLE EDIT screen, press [F3 (MODIFY)] to open 
the Sample Modify Menu window.
 
2.
 
Press [F2 (NORM & AMP)], and then press [F1 (NORM)].
 
fig.NORMALIZE
 
3.
 
If you want to replace the current sample with the 
normalized sample, press [F4 (OVER WRITE)] to display the 
 
 
” mark.
 
4.
 
Press [F6 (EXEC)].
 
A message will ask you for confirmation.
 
5.
 
To execute, press [F6 (EXEC)].
 
*
To cancel, press [F5 (CANCEL)].
 
This operation adjusts the volume of the entire sample. You can also 
apply an envelope (time-variant change) to the volume of the sample.
 
*
You cannot execute this with more than one sample selected.
 
1.
 
In the SAMPLE EDIT screen, press [F3 (MODIFY)] to open 
the Sample Modify Menu window.
 
2.
 
Press [F2 (NORM & AMP)], and then press [F2 (AMP)].
 
fig.AMP
 
3.
 
If you want to adjust the volume of the entire sample, use the 
VALUE dial or [INC] [DEC] to set the rate of volume boost.
 
4.
 
If you want to apply an envelope, specify points.
Press [F3 (POINT)] to display the “
 
 
” mark. Then press [
[
] to select a parameter, and then use the VALUE dial or 
[INC] [DEC] to set the value.
 
5.
 
If you want to replace the current sample with the edited 
sample, press [F4 (OVER WRITE)] to display the “
 
 
” mark.
 
6.
 
Press [F6 (EXEC)].
 
A message will ask you for confirmation.
 
7.
 
To execute, press [F6 (EXEC)].
 
*
To cancel, press [F5 (CANCEL)].
 
Boosting or Limiting the High-
frequency Range of the Sample 
(EMPHASIS)
Maximizing the Volume of a 
Sample (NORMALIZE)
 
AMP
 
Parameter
Explanation
 
Rate
Rate of volume boost: 
 
0–400%
 
Specifies how much boost will be applied relative to the 
current volume
 
Parameter
Explanation
 
Current 
Point
Currently selected point
Beginning near the start point, the points will be num-
bered 1, 2, 3, or 4.
Point 1–4
Location of the current point
Rate 1–4
Amplification ratio of the current point: 
 
0–400%
 
Specifies how the volume of each point is to be boosted 
relative to the current value.
JUNO-G_e.book 121 ページ 2006年7月31日 月曜日 午後2時49分