Roland PCR-300 业主指南
10
Using control maps
The PCR-300/500/800 can receive control map data in the form of a bulk dump.
If you want control map data you’ve created using PCR Editor to be received into the
PCR’s current memory, you’ll need to make settings in PCR Editor so that the PCR will
be ready to receive a bulk dump. If you want the PCR to receive this data as messages
from your DAW software, you’ll need to make settings on the PCR keyboard so that it
will be ready to receive a bulk dump.
Here we’ll explain how to make settings on the PCR keyboard so that it will be able
to receive a bulk dump.
If you want control map data you’ve created using PCR Editor to be received into the
PCR’s current memory, you’ll need to make settings in PCR Editor so that the PCR will
be ready to receive a bulk dump. If you want the PCR to receive this data as messages
from your DAW software, you’ll need to make settings on the PCR keyboard so that it
will be ready to receive a bulk dump.
Here we’ll explain how to make settings on the PCR keyboard so that it will be able
to receive a bulk dump.
fig.H-Edit.eps
1
Press the [EDIT] button so it’s lit.
fig.D-Edit.eps
The display will indicate “EDIT.”
fig.D-Bulk.eps
2
Turn the VALUE knob to make the display indicate “BULK.”
fig.D-BulkR.eps
3
Press the [ENTER] button.
“BLR” will blink in the display (Bulk Receive).
“BLR” will blink in the display (Bulk Receive).
4
Verify that the display indicates “BLR” (Bulk Receive), and then press the [ENTER]
button.
button.
If the display indicates “BLT” (Bulk Transmit), use the VALUE knob to make it
indicate “BLR” (Bulk Receive).
indicate “BLR” (Bulk Receive).
5
Use the VALUE knob or the controllers to choose the reception method. Choose
the method that’s appropriate for the data you’ll be receiving.
the method that’s appropriate for the data you’ll be receiving.
fig.D-RSBulk-Wait.eps
6
Verify that the display indicates the correct choice, and press the
[ENTER] button. The rightmost digit of the display will blink, and
the PCR will wait for bulk data to arrive.
[ENTER] button. The rightmost digit of the display will blink, and
the PCR will wait for bulk data to arrive.
Receiving a control map from your computer (Bulk Receive)
Controller
Item
Display
Explanation
[A1 (0)]
SINGLE
BULK
One control map will be received.
The received data will overwrite the
current memory.
Memories 1–F will not be affected.
The received data will overwrite the
current memory.
Memories 1–F will not be affected.
[A2 (1)]
ALL BULK
Data for all fifteen control maps will
be received. The received data will
overwrite internal memories 1–F.
be received. The received data will
overwrite internal memories 1–F.
About the display in Bulk mode
Transmit
Receive
Transmit
Waiting
(blinking)
Receive
Waiting
(blinking)
ALL
BULK
SINGLE
BULK
Receiving
Transmitting
Receive/Transmit
SINGLE BULK / ALL BULK
Transmitting/Receiving/Waiting
PCR-300_500_800_e.book 10 ページ 2007年2月28日 水曜日 午後7時10分