Dave Smith Instruments mopho 用户指南

下载
页码 52
 34 
 
 
Received NRPN Messages 
 
Status 
Second 
Third 
Description 
1011 nnnn 
0110 0011 
0vvvvvvv 
NRPN parameter number MSB CC 
1011 nnnn 
0110 0010 
0vvvvvvv 
NRPN parameter number LSB CC 
1011 nnnn 
0000 0110 
0vvvvvvv 
NRPN parameter value MSB CC 
1011 nnnn 
0010 0110 
0vvvvvvv 
NRPN parameter value LSB CC 
1011 nnnn 
0110 0000 
0xxxxxxx 
NRPN parameter value Increment 
1011 nnnn 
0110 0001 
0xxxxxxx 
NRPN parameter value Decrement 
1011 nnnn 
0010 0101 
0111111 
RPN parameter number MSB CC — Reset 
NRPN parameter number (when both MSB and 
LSB received) 
1011 nnnn 
0010 0100 
0111111 
RPN parameter number LSB CC — Reset 
NRPN parameter number (when both MSB and 
LSB received) 
 
Global Parameter Data 
The following table shows the Global data that is sent and received on global 
parameter dumps, and the corresponding NRPN number when sent/received 
individually. 
Param 
NRP
Range 
Description 
384 
0 -24 
Master Transpose; 0 = -12 semitones (1 octave), 12 
= 0 (no transpose), and 24 = +12 semitones.  
385 
0- 100 
Master Fine Tune; 0 = -50 cents, 50 = 0 (centered), 
100 = + 50 cents 
386 
0 - 16 
MIDI Channel; if = 0, data received on all MIDI 
channels. Otherwise = channel number 1 — 16. 
388 
0 - 3 
MIDI clock select 
0  Use Internal clock, don’t send MIDI clock 
1  Use Internal clock, send MIDI clock 
2  Use MIDI clock In 
3  Use MIDI clock In, and retransmit MIDI clock out 
390 
0 - 2 
Parameter Send: 
0  NRPN 
1  CC 
2  Off 
391 
0 - 3 
Parameter Receive: 
0  All 
1  NRPN only 
2  CC only 
3  Off 
394 
0 - 1 
MIDI Controller Send/Receive Off/On 
395 
0 - 1 
MIDI Sysex Send/Receive Off/On