Installation
17
Label Sensors
Gap Sensors
Figure 13, Selecting the Gap Sensor
The printer has gap sensors (Figure 13, 1 and 2, receivers in the left picture, 
transmitters in the right picture) which can detect the start and end of a label. 
These sensors are controlled by a switch setting (Figure 13, 3). The switch 
can be set to the left or to the right. All Brady IP enabled material will instruct 
the user, via the front LCD display, which position to set the switch. For 
non-standard material, set the sensor to position 2. Non-standard notched 
material is dependent on specific supply criteria.
1. Open the cove(Figure 1, 9) lower the control panel (Figure 1, 17) , and 
press the green print module release button(Figure 1, 15) .
2. Move the switch (Figure 13, 3) to the left or right as required.
3. Lower the print module. Press firmly on the close points (Figure 1, 12) on 
both sides on the module until the printhead clicks firmly into position.
4. Lift the control panel (Figure 1, 17) and press firmly until the panel clicks 
into position.
5. Close the cover (Figure 1, 9).
NOTE: This switch cannot be made by the software.
1. Gap sensor 1
2. Gap sensor 2
3. Switch