Brady BP-IP300 用户指南

下载
页码 75
Control Panel
52
Interfaces
Press the menu key.
Select Setup > Interfaces.
Barcode 
error
On
: With faulty barcode contents or size 
specifications, printing is interrupted.
Off
: Printing is not interrupted if an error 
occurs. If barcode contents are faulty, the 
printer attempts to replace the incorrect data 
with valid characters (e.g. zeros). If barcode 
size specifications are faulty, a gray area is 
printed instead of the barcode.
On
Width ASCII 
dump
Width of the printing area in the Monitor 
mode test function.
With the Automatic setting, the printout of the 
control sequences arriving at the printer 
occurs over the maximum printing width. You 
can reduce the printing area width down to 
2 inches (50.8 mm).
Automatic
Parameter
Meaning
Default
Default 
card slot
Selects the primary card slot. Select one of the 
card slots on the back of the printer 
(CompactFlash, PC Card or Ext. 
CompactFlash)
Compact
Flash
Character 
set
Selects the character set table.
Switching the character set via software is not 
possible. You can access characters not 
available in the selected character set by using 
the Unicode table.
Windows 
1252
RS-232
Sets the interface parameters Baud rate and 
Handshake for data transfer via the serial 
RS-232 interface.
Recommended settings are 115200 and 
hardware handshake.
115200
RTS/CTS
Parameter
Meaning
Default
widthasc2dump