USER’S GUIDE
122      CyberSWITCH
datalink delete
Deletes an existing data link.
L
INE
 C
ONFIGURATION
 E
LEMENTS
L
INE
 N
AME
A 1 to 16 user-defined character string (using all non-blank characters) that identifies the line. Each 
line must have a unique name. 
L
INE
 S
LOT
The slot number assigned to the resource that will terminate this line.
L
INE
 P
ORT
The port number of the resource that will terminate this line.
L
INE
 I
NTERFACE
 T
YPE
 
For basic rate lines only. Choice of point-to-point or point-multipoint. The point-to-point interface 
type is the type most often used in the U.S.; point-multipoint is most often used in Japan.
A
UTO
 TEI 
For basic rate lines only.The default setting for automatic TEI negotiation is “yes”. For # 5ESS and 
DMS100 lines, you should not change the setting. For NTT point-to-point lines, you should disable 
the automatic TEI negotiation by answering “no” to the prompt for this feature.
C
ALL
 S
CREENING
 M
ETHODS
 
For basic rate lines only. If you select a line interface type of point-multipoint, choose one of the 
following call screening methods: none, subaddress, or telephone number. The paragraphs below 
define each method.
1.
None
All calls will be accepted. 
2.
Subaddress
Uses a configured subaddress for this site. If the subaddress method is chosen, and a 
subaddress has not been configured for this site, an error message will be displayed. You must 
either choose another method, or configure a subaddress for this site. 
3.
Telephone Number
Telephone number(s) for your site used for call screening. Only calls directed to that specific 
telephone number will be accepted. If there is more than one, enter the list of telephone 
numbers separated by commas. After entering the telephone numbers, you will then be asked 
to enter the maximum number of digits (starting at the rightmost digit) to be verified. 
Note:
If the telephone number(s) entered here do not exactly match the number(s) for the site, 
you will be warned at this time. (The number of digits compared will be the number of 
digits you chose to use for verification.)
D
ATA
 L
INKS
 
A data link is a data communications link to the telephone switch. Your Carrier Service can provide 
you with the data link values you need to configure. All switch types, except the DMS100 and the 
NI-1, require a single data link per line. The NI-1 switch type can have either one or two data links 
per line. The DMS100s generally require two data links per line, one for each B channel. For both