Enterasys csx5500 用户指南

下载
页码 729
USER’S GUIDE
208      CyberSWITCH
CSM A
UTHENTICATION
 S
ERVER
C
ONFIGURING
 CSM A
UTHENTICATION
 S
ERVER
Notes:  In order for the CyberSWITCH to reference CSM for device authentication, the following 
configuration steps must first be completed:
IP Routing must be enabled. If you try to enable CSM before IP routing has been 
enabled, an error message will be displayed.
The appropriate LAN network interface(s) must be configured to represent the local IP 
network.
The appropriate WAN network information must be configured for each type of 
remote device configured that will connect to the system.
If you have configured Call Restrictions, you have configured system wide Call 
Restrictions. System wide Call Restrictions will override Call Restrictions configured on 
CSM on a per device basis.
U
SING
 CFGEDIT
1.
Select Security from the main menu.
2.
Select option (5), Off-node Server Information from the Security Menu. The following screen is 
displayed:
3.
Select CSM from the Off-node Server Information Menu. The following screen is displayed:
4.
Enter the TCP port number used by CSM.
U
SING
 M
ANAGE
 M
ODE
 C
OMMANDS
csm
Displays the current CSM configuration data. 
csm change
Allows you to change the CSM TCP port number. 
Off-node Server Information Menu:
   1) CSM
   2) RADIUS
   3) TACACS
   4) ACE
   
Select function from above or <RET> for previous menu: 1
CSM Menu:
           TCP Port Number             is 2000
CSM Server Options:
   1)  CSM TCP Port
   
Select function from above or <RET> for previous menu: 1