Enterasys csx5500 用户指南

下载
页码 729
USER’S GUIDE
262      CyberSWITCH
-- the rate at which data frames may be sent into the network without incurring congestion. This is 
generally accepted as the end-to-end available bandwidth at which frame relay service devices may 
enjoy sustained frame transmission. By definition this must be less than the throughput that the 
actual physical access link can support. However, for short periods of time, service devices may 
exceed this rate by defined values. This excess is known as the excess information rate and is 
defined as the bandwidth available above and beyond the committed rate. The reason this is 
possible is because statistically, not each PVC within the access will make use of its complete 
bandwidth allocation. Busy PVCs may essentially borrow bandwidth from underutilized PVCs. 
The Frame Relay software has the capability to transmit data above the committed information rate 
up to the excess information rate. Note that the sum of the committed and the excess information 
rates must not exceed the rate defined by the physical link. These rates are user-configurable 
options.
C
ONGESTION
 C
ONTROL
 O
VERVIEW
Congestion occurs when traffic arriving at a resource, whether network or user equipment, exceeds 
that node’s capacity. Congestion notification in the device plane is used to inform the equipment 
(at the ingress point to the network) of the congestion, and allows the user equipment to initiate 
congestion avoidance procedures. The intent is to reduce the negative effects on both network and 
user equipment: the user equipment should take corrective action to reduce the congestion, or to 
notify the source that throughput has been exceeded. Congestion control is very important in 
providing reliable frame relay services. Congestion can be detected in two ways, implicitly and 
explicitly. Implicit indications are provided by lost frames whereas explicit congestion indications 
are provided for within the frame relay protocol.
C
URRENT
 R
ESTRICTIONS
Currently, only PVC (Permanent Virtual Circuit) frame relay connections are implemented. 
Through configuration, PVC connections establish a permanent association between two DTEs.
The only types of facilities to be supported for frame relay access are serial interfaces (such as V.35 
and RS-232) and channeled interfaces such as T1/PRI and BRI. However, currently only 1 port per 
channeled interface is supported until SVC standards are available.
Frame relay supports only a single Permanent Virtual Circuit connecting any two given 
CyberSWITCH systems. To illustrate this point, the following diagram shows a frame relay 
network configuration that would be allowed:
"SITE1"
"SITE2"
"SITE3"
Frame Relay
DLCI 1 -> SITE2
DLCI 2 ->SITE3
ALLOWED
CSX5500
CSX5500
CSX5500