Enterasys csx5500 用户指南

下载
页码 729
Central Site Remote Access Switch      349
C
ONFIGURING
 IPX
IPX-Specific Information for Devices
This parameter is only necessary for IPX over Frame Relay when at least one of the 
CyberSWITCHes in the Frame Relay connection is a CSX200 or CSX400. (CSX200 and CSX400 
platforms do not support unnumbered connections). In this instance, you must specify the same 
number on both CyberSWITCHes supporting the Frame Relay access.
IPX R
EMOTE
 LAN N
ETWORK
 N
UMBER
Specifies the IPX external network number on the remote LAN. The default value is none
If you choose to change this parameter, you must specify the IPX external network number used 
on the remote LAN in question. This value must be the same as the value configured for the 
corresponding IPX Remote LAN interface. 
If this parameter remains none, the CyberSWITCH will assume the network number is that of the 
first configured IPX Remote LAN interface. This is convenient in applications in which remote 
LANs consist only of clients (thus no explicit external network address), all of which are on the 
same external virtual LAN.
IPX S
POOFING
 O
PTIONS
For IPX routing, IPX spoofing options are configurable by device, and correspond to the system-
level spoofing options.
For IPX Remote LAN devices, IPX spoofing options are currently not available. 
IPX B
ACKGROUND
 I
NFORMATION
 
FOR
 D
EVICES
To configure your CyberSWITCH for IPX routing, you must properly complete the system 
parameters that are IPX-specific. These parameters are discussed in the first portion of this chapter. 
But, for a remote device to be able to participate in IPX routing or bridging using the IPX Remote 
LAN interface, you also need to configure that device with the necessary IPX information. This 
information is configured in the on-node device database.
IPX T
RIGGERED
 RIP/SAP D
EVICE
 B
ACKGROUND
 
On the on-node device database, choose Triggered RIP/SAP as the IPX protocol for those remote 
devices that will use this protocol to exchange route/service information with the CyberSWITCH. 
You can display these locally-configured remote devices from the
.
When using an off-node server, you need to configure a list of IPX Triggered RIP/SAP routers.
At initialization time, Triggered RIP/SAP starts for all on-node devices whose selected protocol is 
Triggered RIP/SAP. The information about IPX Triggered RIP/SAP may be fetched from an off-
node server, if applicable, and then Triggered RIP/SAP will start for the configured routers.