Enterasys csx5500 用户指南

下载
页码 729
Central Site Remote Access Switch      367
C
ONFIGURING
 C
ALL
 C
ONTROL
Throughput Monitor
T
HROUGHPUT
 M
ONITOR
 C
ONFIGURATION
 E
LEMENTS
S
AMPLE
 R
ATE
A Sample Rate identifies the number of seconds for each sample period. The default setting for the 
sample rate is 5 seconds. During this period, the system keeps track of the total number of bytes 
that is transferred in both directions between two systems. The utilization percentage is determined 
by comparing this total with the realistic maximum for the current aggregate amount of 
bandwidth.
O
VERLOAD
 T
RIGGER
 N
UMBER
The number of samples within the window that must exceed the specified utilization for the 
OVERLOAD condition to occur.
O
VERLOAD
 W
INDOW
 S
IZE
The number of sample periods (up to 32) that you should use as the sliding window.
O
VERLOAD
 P
ERCENT
 U
TILIZATION
The percentage of the available bandwidth that the traffic samples must exceed for an overload 
condition to occur. 
U
NDERLOAD
 T
RIGGER
 N
UMBER
The number of samples within the window that must be below the next lowest target capacity for 
the UNDERLOAD condition to occur.
U
NDERLOAD
 W
INDOW
 S
IZE
The number of sample periods (up to 32) that you should use as the sliding window.
I
DLE
 T
RIGGER
 N
UMBER
The number of samples within the window that must be below the specified utilization for the 
IDLE condition to occur.
I
DLE
 W
INDOW
 S
IZE
The number of sample periods (up to 32) that you should use as the sliding window.
I
DLE
 P
ERCENT
 U
TILIZATION
The percentage of available bandwidth on the last connection that traffic samples must fall below 
for the connection to be considered IDLE.
Note:
The system monitors for the IDLE condition when only one connection to a site exists, and 
that connection is a switched connection.
T
HROUGHPUT
 M
ONITOR
 B
ACKGROUND
 I
NFORMATION
A powerful feature of the CyberSWITCH is its ability to add and drop calls depending on the 
amount of WAN traffic. If no information is being sent, the call will be terminated. The system will 
also make additional calls to a site if it is determined that extra bandwidth is needed.
The Bandwidth Management feature works by sampling the amount of data that is transmitted and 
received on the connections between two units. Each sample is compared to the levels associated 
with the different conditions. The results of these comparisons are kept in a sliding window. The 
window size, number of samples that trigger an event, and sampling frequency are configurable.