Select Call Intervals from the Call Control Options menu.
2.
Enter the minimum time interval between call attempts.
C
ALL
 I
NTERVAL
 C
ONFIGURATION
 E
LEMENTS
M
INIMUM
 T
IME
 I
NTERVAL
The configured call interval is the minimum time between call attempts. The system will not make 
a call attempt in less than the configured call attempt value. However, due to the system hardware 
clock resolution, the actual time interval may be greater than the configured value. The default 
value is 0.70 seconds. The range of the configured value is 0 to 5 seconds, in 1/100 second 
increments. A configured value of 0 implies that the system will make call attempts without any 
delay between them.
C
ALL
 I
NTERVAL
 B
ACKGROUND
 I
NFORMATION
This parameter allows the configuration of the minimum interval between call attempts. This 
interval applies to the entire system, including all lines, sites, and devices.
The Call Interval is configured in terms of hundredths of seconds. The default value is .7 seconds. 
The range of the configured value is 0 to 5 seconds. A configured value of 0 implies that the system 
will make call attempts without any delay between them.
The default value of .7 seconds is compliant with the Communications Industries Association of 
Japan’s(CIAJ) regulation. This regulation states that no customer premise equipment should make 
more than 3 call attempts within 2 seconds. This prevents certain model switches from being 
overloaded. In areas where these low capacity switches are not installed, calls can be made more 
frequently.
Before the system initiates a data connection, it first checks the time at which the last connection 
was initiated. If the time from the last connection attempt to the new connection attempt is less than 
the configured call interval, the new connection is placed on an outgoing call queue. The queue is 
then serviced at the configured call interval. 
M
ONTHLY
 C
ALL
 C
HARGE
 
C
ONFIGURING
 M
ONTHLY
 C
ALL
 C
HARGE
U
SING
 CFGEDIT
1.
Select Call Charges from the Call Control Options menu.
2.
Follow the onscreen instructions to enable this feature.
3.
Enter the maximum monthly charge you would like to set (specified in Yen for NTT 
connections).
4.
Select the action to take if the maximum is exceeded.