Enterasys csx5500 用户指南

下载
页码 729
Central Site Remote Access Switch      431
V
ERIFYING
 
THE
 B
ASE
 S
YSTEM
Alternate Accesses
5.
Display the system log (
dr
 command). If the feature is operational, some frames similar to the 
following will be displayed:
(I) 16:28:49.71 #C021: Conn=001 OUT-PPP:LCP      ECHO REQ Id=0x50 Len=10
(I) 16:28:49.71 #0000:   3E 03 78 AC
(I) 16:28:49.76 #C021: Conn=001 IN -PPP:LCP      ECHO RPLY Id=0x50 Len=10
(I) 16:28:49.76 #0000:   70 18 D0 87
(I) 16:28:59.82 #C021: Conn=001 OUT-PPP:LCP      ECHO REQ Id=0x51 Len=10
(I) 16:28:59.82 #0000:   3E 03 78 AC
(I) 16:28:59.82 #C021: Conn=001 IN -PPP:LCP      ECHO RPLY Id=0x51 Len=10
(I) 16:28:59.82 #0000:   70 18 D0 87
6.
To determine if the feature detects a failure:
a.
Set up two systems in a back-to-back, dedicated, BRI scenario where at least one of the 
systems is a PC-Platform. Configure a dedicated access between the 2 systems.
With the a PC-based platform, layer 1 of a BRI board stays active even when you exit the 
software. This gives us a way to simulate an end-to-end B-channel failure. That is, the only 
remaining way for the other system to detect the error is via the Link Failure Detection 
mechanism. (There are no D-channel failures or Layer 1 failures).
b.
On the non-PC system (or either of the two if both are PC-platforms), make sure that Link 
Failure Detection is enabled. Go to the 
mc
 screen to make sure that the dedicated 
connection is up.
c.
On the PC-platform system, enter the 
quit
 command.
d. On the non-PC system wait for approximately the amount time of the echo frequency 
multiplied by the maximum attempts. At this time, the feature should detect the failure, 
and the 
mc
 screen should remove the dedicated connection.
e.
Check the log for the message which indicates that a link failure has been detected.
f.
If there is a failure, refer to 
 for corrective actions.
X.25 C
ONNECTIONS
To verify an X.25 to the CyberSWITCH, the WAN lines that are connected to the System must be 
available for use, and the routing option must be properly initialized.
1.
Enter the 
x25 stats 
command at the administration console. If the statistics display appears, 
the X.25 subsystem should be operational. 
2.
 If the message: 
No X.25 Accesses configured
 is displayed, verify your configuration. 
Using CFGEDIT, verify that the proper line and port have been selected. If you are still having 
problems, try the following:
a.
Enter the 
er
 command to erase the report log.
b.
Enter the
 trace lapb on
 command.