Enterasys csx5500 用户指南

下载
页码 729
Central Site Remote Access Switch      471
V
ERIFYING
 S
YSTEM
 O
PTIONS
Verifying a Semipermanent Connection
3.
On the CyberSWITCH:
a.
Enable the call trace message option by issuing the 
trace on 
console command.
b.
Erase the current system messages (issue the 
er
 console command).
c.
Initiate a call from the remote device to the CyberSWITCH.
d. The remote device should indicate it is waiting for a callback.
e.
Display the system messages (issue the 
dr
 console command). You should see the 
incoming call and possibly some proceeding/alerting messages, a connect, then a 
disconnect. In approximately 300 seconds, you should see an outgoing call to the remote 
site and a connect message.
f.
The remote device should answer the incoming call and connect.
4.
If the modem answers but n o pop up screen comes up to prompt for a callback number, make 
sure the callback checkbox is checked for this device through CSM.
5.
If you enter the phone number in the callback pop up but no call back ever occurs, check the 
following:
a.
Make sure you entered the correct number in the callback pop up.
b.
Check to see if the phone number entered needs a Centrex digit (a 9 before the phone 
number).
V
ERIFYING
 
A
 S
EMIPERMANENT
 C
ONNECTION
Follow the same procedure outlined in th
section. If you can successfully use the call 
device command to call the device assigned to the semipermanent connection, then the connection 
is working. If not, follow the instructions actions in the dial out verification section.