Enterasys csx5500 用户指南

下载
页码 729
USER’S GUIDE
56      CyberSWITCH
C
LEANING
 
THE
 NE 5000 A
IR
 F
ILTER
The NE 5000 has a removable air filter. This filter is provided to ensure system cleanliness and 
stability in dusty operating environments. The filter is located just behind the chassis’ front panel. 
For best performance (and as an alternative to replacement) regularly wash the filter in warm water 
and a mild detergent.
Before removing the air filter for cleaning, read the following warning and caution notes.
WARNING
Before removing the air filter for cleaning, ensure that the system is powered off and the power 
cord is unplugged from the power source. Note that the Power ON/OFF switch does not 
disconnect the power from the system. Failure to unplug the power cord can result in serious 
injury or equipment damage.
CAUTION
An electrostatic discharge (ESD) can damage your system. We recommend that you perform 
this procedure only at an ESD workstation. If such a workstation is unavailable, provide some 
ESD protection by wearing an antistatic wrist strap attached to chassis ground when handling 
components.
To clean the air filter:
1.
Power-down the system and disconnect the system’s power cord from the power source.
2.
Remove the system’s top cover.
3.
Remove the two retaining screws holding the air filter in place.
4.
Tilt the filter toward the rear of the chassis and lift the filter up and out of its position.
5.
Once removed, you can clean the filter by washing it in warm water and a mild detergent. 
Make sure it is completely dry before you place it back in the system.