Lenovo d20 4158 硬件手册

下载
页码 264
Diagnostic Error Code
FRU/Action
001-032-XXX
System Device Controller failure
System board
001-034-XXX
System Device Buffer Allocation failure
1.
Reboot the system
2.
3.
Run memory test
4.
System board
001-035-XXX
System Device Reset condition detected
System board
001-036-XXX
System Register error
System board
001-038-XXX
System Extension failure
1.
Adapter card
2.
System board
001-039-XXX
System DMI data structure error
1.
2.
System board
001-040-XXX
System IRQ failure
1.
Power-off/on system and re-test
2.
System board
001-041-XXX
System DMA failure
1.
Power-off/on system and re-test
2.
System board
001-195-XXX
System Test aborted by user
Information only
Re-start the test, if necessary
001-196-XXX
System test halt, error threshold exceeded
1.
Press F3 to review the log file
2.
Re-start the test to reset the log file
001-197-XXX
System test warning
1.
Make sure the component that is called
out is connected and/or enabled. See
Chapter 6, “Using the Setup Utility,” on
page 51
2.
Re-run test
3.
Replace the component that is called out
in warning statement
4.
Replace the component under test
001-198-XXX
System test aborted
1.
If a component is called out, make sure
it is connected and/or enabled. See
Chapter 6, “Using the Setup Utility,” on
page 51
2.
Flash the system and retest. See “Flash
update procedures” on page 251
3.
001-199-XXX
System test failed, cause unknown
1.
2.
Flash the system and re-test
3.
Replace component under function test
001-250-XXX
System ECC error
System board
68
Hardware Maintenance Manual