Configure drives
transmitted data at one end of the transaction, then the 
parity data is checked  at the other end to make sure the  
transmission has not had any errors. 
In the array, transmitted data with the added parity data 
is striped across disk drives. A hardware XOR engine 
computes parity, thus alleviating software processing 
during reads and writes. 
The array operates in degraded mode if a drive fails. 
Interleave
The interleave size sets the amount of data to be 
written to each drive in a RAID group. This is a 
tunable parameter which takes a single stream of data 
and breaks it up to use multiple disks per I/O interval. 
The CLI command RAIDInterleave allows you to 
change the size of the sector interleave between RAID 
groups. The value will depend upon the normal 
expected file transfer size. If the normal file transfer 
size is large, the interleave value should be large, and 
vice versa.
The value entered for the RAIDInterleave command 
refers to blocks of data: one block is equivalent to 512 
bytes of data.
Valid entries are 16, 32, 64, 128, 256 and SPAN. 
SPAN, not available in RAID Level 5, indicates that 
interleave size between the drives in the group will be 
the minimum drive size of all members in the group.
Partitions
With the introduction of larger and larger GB-sized 
drives, the array may have up to 7.2 TB total data 
capacity. Partitioning can increase storage efficiency 
by providing more LUNs without using lower capacity 
RAID groups.
Partitioning allows the creation of multiple logical 
volumes. Long LBA (64 bit addressing) allows you to 
take full advantage of the increasing storage capacity 
made possible through the new high capacity disk 
drives. Applications and host operating systems which 
do not support Long LBAs are able to access larger 
array capacities which otherwise would not have been 
possible. 
Using the CLI or by accessing the Advanced CLI 
configuration page in the ExpressNAV interface, you 
are able to divide an individual Partition into a set of 
equally-sized subpartitions which can then be 
presented to hosts as separate LUNs.
Zones
Zoning is a collection of related Diamond capabilities 
supporting flexible array configuration management 
configurable via CLI commands in the CLI or the 
Advanced CLI configuration page of the 
ExpressNAV interface. Zoning supports security by 
granting or denying access between initiators and 
devices as defined by an administrator. 
A zone is a collection of devices which can access 
each other. The devices in a zone usually include one 
or more initiators, one or more devices, and one or 
more paths between the initiators and the devices.
Hot Spare sleds
In most configurations, if a member of a virtual device 
becomes degraded, you must swap out the faulted sled 
as defined in Hot Swap Operating Instructions on page 
87
. I
f you have not enabled AutoRebuild, you must 
also start a manual rebuild.
For four configurations, however, Hot Spare sleds may 
be designated as replacements for faulted sleds 
without intervention by you or a host. 
Each configuration requires a certain number of Hot 
Spare sleds. These sleds, once designated as Hot 
Spares, are not available for other use.
The following configurations support optional Hot 
Spare sleds:
RAID Level 1:  
2 Hot Spare sleds 
RAID Level 10:  
1 group, 2 Hot Spare sleds 
RAID Level 5: 
1 group, 1 Hot Spare sled 
RAID Level 5:  
2 groups, 2 Hot Spare sleds
Enhancing performance
SpeedWrite, enabled by the CLI command 
SpeedWrite, improves the performance of WRITE 
commands