ATTO Technology diamond array v 用户手册

下载
页码 117
78
Monitors, reports
disabled. When the ambient temperature 
decreases to within standard operating range, the 
drives are powered back on and the host is 
allowed to access data.Typical Diamond Storage 
Array operation over a range of external ambient 
temperatures. Alarms are audible, visual, CLI and 
SES cues as described above.
Exhibit 8.0-1  Typical Diamond Storage Array operation over a range of external ambient temperatures. Alarms are 
audible, visual, CLI and SES cues as described above.
Power Supply Monitoring  
The array monitors the 
operation of its power supplies and blower 
assemblies every 30 seconds. If the status 
changes, the system reports it visually with an 
LED and a message in the CLI. 
If a power supply or blower fails, the management 
system sends a CLI message and turns off the 
corresponding power supply LED. 
The blower assembly directly adjacent a power 
supply must be functioning properly for the power 
supply to work properly. If a blower assembly 
fails, the power supply shuts down and the 
management system sends a CLI message. The 
corresponding power supply LED on the system 
management card also turns off. 
If a good replacement power supply or blower 
assembly is inserted into the array, the 
management system sends a CLI message and the 
corresponding system management card LED 
lights. It may take up to 30 seconds for the system 
to note these changes.
System Fault LED and Error Codes 
If a serious 
hardware or software error occurs in the array, the 
System Fault LED displays a series of flashes or 
blink codes. Error information is reported via the 
CLI if it is operational.
At power up, the green array Ready (RDY) LED 
turns on after successful completion of the POST 
(Power On Self Test) indicating the array is 
available for normal operation. 
During operation, the Ready LED stays lit even if 
the amber Fault (FLT) LED lights.
If a serious error occurs in the array, the amber 
Fault LED flashes repeatedly in a blink code 
pattern: 
•  an initial series of blinks indicating the system 
problem
•  a two second pause
•  another series of blinks providing more detailed 
information for technical personnel.
•  a four-second pause
•  the blink code sequence repeats from step 1 
until the error is cleared.
In general, any fault requires notification of 
Diamond Storage Array technical personnel for 
resolution or for further debug instructions. When 
you report an error code, please provide both the 
first and second blink code values.
During a fault condition, more detailed 
information about the fault may be available via 
the CLI or the ExpressNAV interface over the RS-
232 interface port or the optional Ethernet port. 
Temperature
25°C
25°C
32°C
32°C
35°C
35°C
40°C
40°C
Condition
blowers 
OK
1 blower 
fails
blowers 
OK
1 blower 
fails
blowers 
OK
1 blower 
fails
blowers 
OK
1 blower 
fails
Read/Writes
normal
normal
normal
normal
normal
normal
normal
Array 
offline
Alarms
OK
OK
OK
OK
OK
WARNING
OK
CRITICAL
Number of blinks
Problem area
1, 2 or 3
processor or memory
4
Fibre Channel interface
5
SCSI interface
7
Fibre Channel connection
8
general internal processing
9
SCSI Enclosure Services