ATTO Technology diamond array s 用户手册

下载
页码 105
81
 
ATTO Technology Inc. Diamond Storage Array Installation and Operation Manual
•  a two second pause
•  another series of blinks providing more detailed 
information for technical personnel.
• a 
four-second 
pause
•  the blink code sequence will repeat from step 1 
until the error is cleared.
In general, any fault will require notification of 
Diamond Array technical personnel for resolution 
or for further debug instructions. When you report 
an error code, please provide both the first and 
second blink code values.
During a fault condition, more detailed 
information about the fault may be available via 
the CLI over the RS-232 interface port or the 
optional Ethernet port. These error messages 
should be reported to technical personnel to assist 
in debugging the problem. 
The blink codes are also saved internally by the 
array to NVRAM (Non Volatile Random Access 
Memory) and will be displayed at power up if the 
power to the array is recycled. 
Disk drive activity and disk fault LEDs
Each dual disk drive sled assembly contains two 
green activity LEDs and an amber Disk Fault 
LED. Once the system has successfully powered 
up and passed POST, the green activity LEDs are 
full on and the Disk Fault LED off. 
The Drive 1 and Drive 2 activity LEDs will stay 
full on when the system is operational and no disk 
drive activity is present. As the disk drives are 
accessed, the green LEDs will flash. If the disk 
drives are heavily accessed the green activity 
LEDs will appear to flash at a high rate or may 
even appear to be completely turned off. 
The amber Disk Fault LED will be off under 
normal operation. If either of the disk drives on a 
dual disk drive assembly reports a disk error of 
any kind, the amber Disk Fault LED will come on. 
The Disk Fault LED can be activated by minor 
issues such as a disk drive writing to a bad sector 
(which is usually corrected by the disk drive the 
next time it writes) or major issues such as a head 
crash or complete drive failure. 
When the Disk Fault LED is turned on, the system 
will issue a detailed message via the CLI. These 
messages are not written permanently to the error 
log file but should be recorded to help assess the 
disk problem. 
If the disk drive error is a non fatal error and the 
drive is still functional, the array will continue to 
read and write data to the disk drive but the Disk 
Fault LED will remain on. If you repeat a drive 
command or action and it completes successfully, 
the Disk Fault LED may have been set by an 
anomaly in the disk drive. You can clear the Disk 
Fault LED by either power cycling the array or 
issuing the SledFaultLED command in CLI as per 
If you repeat a disk command or action and the 
Disk Fault LED remains on, the disk error may be 
serious. You should write down the error message 
issued by the CLI and contact technical support 
via the means easiest for you for assistance (refer 
to 
on page viii). If you 
choose to replace the suspected faulty dual disk 
drive sled assembly, follow the appropriate 
procedures.
Number of blinks
Problem area
1, 2 or 3
processor or memory
4
Fibre Channel interface
5
SCSI interface
7
Fibre Channel connection
8
general internal processing
9
SCSI Enclosure Services