Zhone 7995 用户指南

下载
页码 154
B. Standards Compliance for SNMP Traps
B-6
 
 May 2002
7990-A2-GB20-00
enterpriseFallback
AutoRate(13)
After a loss of signal, the unit 
resynchronized to a lower 
rate than the last known rate.
Variable bindings:
„
ifIndex (RFC 1573)
„
ifAdminStatus 
(RFC 1573)
„
ifOperStatus (RFC 1573)
„
ifType (RFC 1573)
Variable line conditions.
enterprisePrimary-
ClockFailClear(101)
The STU-C has recovered 
and is using its primary clock 
source.
No variable bindings.
enterpriseSecondary-
ClockFailClear(104)
The STU-C has recovered 
and is using its secondary 
clock source.
No variable bindings.
enterpriseTest-
Stop(105)
All tests have been halted.
Variable bindings:
„
ifIndex (RFC 1573)
„
ifAdminStatus 
(RFC 1573)
„
ifOperStatus (RFC 1573)
„
ifType (RFC 1573)
„
ifTestType (RFC 1573)
All tests on an interface have 
been stopped by timeout or an 
Abort All Tests command.
enterpriseFallback
AutoRateClear(113)
After an AutoRate fallback 
condition, the unit 
resynchronized to the 
last known rate.
Variable bindings:
„
ifIndex (RFC 1573)
„
ifAdminStatus 
(RFC 1573)
„
ifOperStatus (RFC 1573)
„
ifType (RFC 1573)
The units automatically 
retrained at the same rate, were 
reset, or placed in fixed rate.
Table B-5.
Enterprise-Specific Traps  (2 of 2)
SNMP Trap
Description
Possible Cause