Jet 350125 jmd-15 - jmd-15 milling 用户指南
8
Lubrication
Lubricate ball oilers (A, Fig. 4) found by the X/Y-
axis hand wheels, the oiler found by the
raising/lowering crank handle, and the oiler on
the front of the bed once daily with Mobil DTE
®
Oil Heavy Medium.
Lubricate the ways (B, Fig. 4) once daily with
Mobil DTE
Lubricate the ways (B, Fig. 4) once daily with
Mobil DTE
® Oil Heavy Medium.
If the head does not rise or lower smoothly,
apply Mobilith AW2 to the rack, and Mobil DTE
®
Oil Heavy Medium to the column.
If the feed handles do not turn smoothly, apply
Mobilith AW2 to the cross and longitudinal lead
screws (C, Fig. 4). Access the cross lead screw
by moving the table forward and removing the
way cover.
The spindle bearings are permanently sealed
and require no lubrication.
If the feed handles do not turn smoothly, apply
Mobilith AW2 to the cross and longitudinal lead
screws (C, Fig. 4). Access the cross lead screw
by moving the table forward and removing the
way cover.
The spindle bearings are permanently sealed
and require no lubrication.
Electrical Connections
A qualified electrician must
make all electrical connections. Failure to
comply may cause serious injury.
comply may cause serious injury.
Before making any electrical connections, make
sure the power source available is compatible
with the machine. Also, turn the machine OFF
using the buttons or switch at the front of the
machine before connecting to the power source.
The JMD Mill/Drills are rated at 115/230V and
come from the factory prewired at 115V. The
mill/drill comes with a plug designed for use on a
circuit with an outlet that looks like the one in
Fig. 5, and has a grounding prong as illustrated
in Fig. 5.
To switch the Mill/Drill to 230V operation:
1. Disconnect machine from power source.
2. Remove junction box cover on the motor.
3. Change the wires according to the diagram on
the inside of the junction box cover, and
reinstall junction box cover.
reinstall junction box cover.
4. Replace thermal relay with one rated for 230V
operation (see parts list).
5. Change power plug to one rated 230V, or hard
wire the power cord.
Make sure the mill/drill is properly grounded.