Maytag MHW6000X 安装指导

下载
页码 20
5
INsTaLLaTION INsTrUCTIONs
NOTE:
 To avoid floor damage, set washer onto cardboard 
before moving it.
36"
(914 mm)
1.
 
Move washer
It is necessary to remove all shipping materials for proper  
operation and to avoid excessive noise from washer. 
Move washer to within 4 ft (1.2 m) of its final location. It must  
be in a fully upright position.
eLeCTrICaL reQUIreMeNTs
n
A 120 volt, 60 Hz., AC only, 15- or 20-amp, fused electrical 
supply is required. A time-delay fuse or circuit breaker is  
recommended. It is recommended that a separate circuit 
breaker serving only this appliance be provided.
n
  This washer is equipped with a power supply cord having  
a 3 prong grounding plug.
n
  To minimize possible shock hazard, the cord must be plugged 
into a mating, 3 prong, grounding-type outlet, grounded in  
accordance with local codes and ordinances. If a mating outlet 
is not available, it is the personal responsibility and obligation 
of the customer to have the properly grounded outlet installed 
by a qualified electrician.
n
  If codes permit and a separate ground wire is used, it is  
recommended that a qualified electrician determine that  
the ground path is adequate.
n
Do not ground to a gas pipe.
n
Check with a qualified electrician if you are not sure the 
washer is properly grounded.
n
  Do not have a fuse in the neutral or ground circuit.
GROUNDING INSTRUCTIONS
For a grounded, cord-connected washer:
This washer must be grounded. In the event of a malfunction 
or breakdown, grounding will reduce the risk of electrical 
shock by providing a path of least resistance for electric 
current. This washer is equipped with a cord having an 
equipment-grounding conductor and a grounding plug. The 
plug must be plugged into an appropriate outlet that is 
properly installed and grounded in accordance with all local 
codes and ordinances.
WARNING: 
Improper connection of the equipment-
grounding conductor can result in a risk of electric shock. 
Check with a qualified electrician or serviceman if you are in 
doubt as to whether the appliance is properly grounded.
Do not modify the plug provided with the appliance – if it will 
not fit the outlet, have a proper outlet installed by a qualified 
electrician.
For a permanently connected washer:
This washer must be connected to a grounded metal, 
permanent wiring system, or an equipment grounding 
conductor must be run with the circuit conductors and 
connected to the equipment-grounding terminal or lead on 
the appliance.
2.
 
Locate transport bolts
Locate four transport bolts on rear of washer.