Making the Connections
MAKING THE ELECTRICAL CONNECTION
  1.    The dishwasher operates on a 120 Volt, 60 Hz electrical supply.  Provide 
a separate circuit with fuse or circuit breaker rated for at least 15 amps (20 
amps if connected with a disposer), but not more than 20 amps.
  2.    Note the location of the electrical supply and the dishwasher’s electrical 
junction box on the right hand underside of the unit.  See Figure 2, page 9.
  3.   Cut the access hole in the shaded area shown in Figure 1, page 7.
  4.  Pull the electrical cable through the hole into the installation area.
MAKING THE WATER CONNECTION 
  1.    Determine where you connect to the hot water supply.  Review Figure 2
page 9 and note the location of the water inlet valve.
  2.    Be sure water inlet is protected from freezing. If valve freezes and 
ruptures, flooding may occur.
  3.    Determine the amount of tubing needed to connect the hot water supply to 
the unit’s water inlet valve.  Copper tubing must have a minimum of 3/8” OD.  
High-pressure and high-temperature rated plastic tubing with a minimum 
inner diameter of 1/4” may be used.  A shut-off valve installed outside the 
dishwasher cabinet is recommended.  See Figure 3, page 11.
CAUTION
Property Damage – Do not use the furnished drain hose or a rubber garden hose for the 
water supply line.  Either of the hoses can burst.  Flooding may occur and cause property 
damage.  Property damage resulted from actions described will void the warranty.
An existing or new, copper or stainless steel braided line, rated for dishwasher use, should 
attach the dishwasher to the water supply line.