IQinVision iq510 参考指南

下载
页码 60
 
Page 9 of 60 
In order to change permanent parameters using the set.oid URL the request must be authenticated using either 
basic or secure authentication.  Basic authentication can be specified by including the username and password 
as part of the URL.  If the privileged password has not been changed use the URL: 
http://root:system@<camera_ip>/set.oid?OidTB2.4=”IQcam” 
This URL will permanently change the camera name to “IQcam” in both the runtime system and non-volatile 
memory. 
Note: 
Internet Explorer does not allow basic authentication to be specified as part of a URL.  
3.4. Efficiently setting multiple OID values 
To efficiently set multiple OID values use the runtime option to change them all in the currently running 
system.  When all OIDs in a functional group have been specified then write the single “Write to NVR” OID 
for the functional group.  This will commit all the runtime values to the flash memory.