Milan mil-sm2401maf 用户指南

下载
页码 178
 
                                                                               
 
5
 
Fault status detect 
Null: no PD present 
Overload: current support over 475mA @ DC 48V and 
over 50 milliseconds 
DR fail: PD discovery resistor is not in the limited range 
Parametric 
information 
It will show current PD parameters, it include 
Discover-resistor detected value, current, voltage, power 
consumption, classification current and determined class 
Port configuration 
control 
Port Disable / Enable. 
PD detect control (enable/disable), Classification detect 
control (enable/disable), DC disconnect detect control 
Mode status 
System detects status, it will show I –sample, V-sample 
and R-detect. 
NTP 
Supports RFC 2030 Simple Network Time Protocol 
(option) 
SMTP 
Supports RFC2821 Simple Mail Transfer protocol 
(option) 
System Log 
System Log record up to 1000 entries 
Power monitor 
Support power supply monitoring function for AC power, 
DC power, fan status 
3 types of power supply can be installed with POE switch, 
POW-DPW, POE-SPW, and POE-UPW. 
Power testing 
Support test function to testing power supply