Runco SP-42 用户指南

下载
页码 84
44
Runco CinemaWall SP Series Owner’s Operating Manual
PRE
L
IMINAR
Y
9. Repeat steps 1 through 8 as desired to create additional screen maintenance 
programs. 
To clear a screen maintenance program, move the cursor to the DATE field and press 
CLEAR on the remote control, using a straightened paper clip or similar object. 
Select Return to exit the Program Timer menu. 
Test Pattern: Select Test Pattern from the Option menu to display an inverse of the 
normal picture on-screen, or a single color. Use this feature to repair burned-in areas of 
the display. 
Press SET repeatedly to select INVERSE or a single color to display. Then, press MENU
To select a different pattern or return to the normal picture, press the Installer Adjust menu 
button, select Option, then select Test Pattern. Press SET repeatedly to select OFF or 
another pattern. 
Sidebar Adj.: Select Sidebar Adj. from the Option menu to adjust the color of the sides 
of the screen when the Aspect Ratio is set to Standard 4:3 or 14:9 (refer to Table 4-1). 
The range is from 0 to +255 for each color component (red, green and blue); the default 
setting is +80 (gray). 
When the 4:3 or 14:9 aspect ratio is selected, the CinemaWall can gradually shift the 
inactive areas of the display in small increments every time it is turned on, to prevent 
burn-in at the sides of the panel. To enable this feature, select Auto Side Mask from the 
Sidebar Adj. menu and set it to ON. 
Select Return to exit the Sidebar Adj. menu. 
Baud Rate: The defaulBaud Rate setting is 9600BPSDo not change it unless 
specifically instructed to do so by Runco Technical Support!
 
ID Number: The ID Number uniquely identifies the CinemaWall in multiple-panel or 
video-wall installations. It is used to address serial commands to a specific panel when 
two or more are daisy-chained together via the COMBINATION IN/OUT connectors (see 
Figure 2-2). For installations with only one CinemaWall, leave the ID Number set to 01
Fan SpeedSelect Fan Speed from the Option Menu to control the operation of the 
CinemaWall’s cooling fan. 
In most cases, the default Fan Speed (AUTO) will maintain the correct operating 
temperature. If the CinemaWall frequently turns off due to overheating, or in certain 
high-altitude operating environments, you may need to change this setting to MAX. 
OSD: Select OSD from the Option menu to set options relating to OSD menu appearance 
and behavior. 
• Display: When you select an aspect ratio or input with the remote control, the 
CinemaWall displays your selection on-screen. When you adjust the volume or press 
MUTE on the remote control, a slidebar appears as a visual indicator of the level. 
To prevent the display of these items, select Display from the OSD menu and set it to 
OFF. 
• Size: Select Size from the OSD menu to change the OSD menu size (SMALL or 
LARGE).
Select Return to exit the OSD menu. 
Front L.E.D.: Select Front L.E.D. from the Option menu to change the behavior of the 
INPUT 3
INSTALLER ADJ.
SCREEN
SET-UP
OPTION
PICTURE
FAN SPEED
 
OSD
:  AUTO
FRONT L.E.D.
 
 
 
ISF SETTINGS
:  ISF CCC
:  ON
RUNCO PRO
FRC
:  NORMAL
ENTER
SET
EXIT
MENU