Runco VX-6000d Installation/Operation Manual
77 
PRE
L
IMINAR
Y
5.1 
Lamp Replacement
The lamp should be replaced when it reaches the end of its life (typically 2000 hours), or 
sooner if a noticeable degradation in brightness occurs. Contact your Runco dealer to 
obtain a replacement lamp.
1.
Turn off the projector and unplug the power cord. Allow the projector to cool down for 
approximately 45 minutes prior to removing the lamp assembly for replacement.
2.
Using a flat-blade screwdriver, loosen the two 
captive Lamp Cover screws on the side of the 
projector and remove the cover.
 
 
 
 
 
 
 
 
 
3.
Remove the three Phillips round-head lamp 
assembly mounting screws. These are identified by 
arrows pointing to them on the lamp housing. 
4.
Grasp the lamp assembly handle and pull gently, removing the lamp module from the 
projector housing.
5.
Install the new lamp module. Secure it in place with the three screws that you 
removed in Step 3. 
6.
Replace the lamp cover and re-tighten the two Lamp Cover screws.
7.
Turn the projector on. 
8.
Reset the Lamp Hour counter by doing either of the following: 
• On the projector rear-panel keypad (see Figure 2-7), press and hold the 
ENTER
 and 
 buttons simultaneously. Then, press the POWER button. 
• On the DHD Controller front panel (see Figure 2-3), while pressing and holding 
the ENTER button, press the POWER (
button. 
When you do, “LAMP 0000H” appears on-screen to confirm the counter reset. 
5. Maintenance and Troubleshooting
Always reset the Lamp Hour counter when you replace the lamp. 
Do this only if you have just installed a new lamp. This will ensure 
that number of hours logged on the lamp is accurate.
REMOVE
THESE SCREWS