Planar PE171 产品用户手册
6
Chapter 3 Technical Information
Specifications
LCD Panel AU Hydis
Size
17" (43 cm)
17" (43 cm)
Display Type
Active matrix color TFT LCD
Active matrix color TFT LCD
Resolution
1280 x 1024
1280 x 1024
Display Dot
1280 x (RGB) x 1024
1280 x (RGB) x 1024
Display Area (mm)
337.92 x 270.336 (H x V)
337.92 x 270.336 (H x V)
Display Color
262K
262K
Brightness
260 cd/m
2
(typical)
250 cd/m
2
(typical)
Contrast Ratio
400:1 (typical)
430:1 (typical)
Response Time
Ta=25°C Tr+ Tf=16ms
Ta=25°C Tr+Tf=20ms
Lamp Voltage
700 Vrms (typical)
705 Vrms (typical)
Lamp Current
7.0 mA rms. (typical)
6.5 mA rms. (typical)
Viewing Angle
Vertical: -70° ~ +70°
Horizontal: -70° ~ +70°
Horizontal: -70° ~ +70°
Vertical: -65° ~ +65°
Horizontal: -80° ~ +80°
Horizontal: -80° ~ +80°
Display Colors
16.7M with FRC or Dithering
Video
Input Signal
Input Impedance
Polarity
Amplitude
Multi-mode Supported
Input Impedance
Polarity
Amplitude
Multi-mode Supported
Analog RGB 0.7Vp-p/ Digital TMDS
75 Ohm ± 2%
Positive, Negative
0 - 0.7 ± 0.05 Vp
Horizontal Frequency: 24 ~ 80 KHz
Vertical Frequency: 56 ~
75 Ohm ± 2%
Positive, Negative
0 - 0.7 ± 0.05 Vp
Horizontal Frequency: 24 ~ 80 KHz
Vertical Frequency: 56 ~
75 Hz
Control
Power switch
(hard and soft types)
(hard and soft types)
On/Off switch with LED indicator
OSD
Brightness
Contrast
Horizontal Position
Vertical Position
Phase
Clock
Display Mode Setup
OSD Format
Contrast
Horizontal Position
Vertical Position
Phase
Clock
Display Mode Setup
OSD Format
Digital
Digital
Digital
Digital
Digital
Digital
Use EEPROM to save settings in memory
20 characters x 9 rows
Digital
Digital
Digital
Digital
Digital
Use EEPROM to save settings in memory
20 characters x 9 rows
Power Management
Mode
Power Consumption*
AC Input
LED Color
On 48W
maximum
240 VAC
Green
Off 3W
maximum
240 VAC
Yellow
Soft switch off
3W maximum
240 VAC
Dark
Disconnected 3W
maximum 240 VAC
Yellow: Standby, Suspend, Off
Dark: DC Power off
Hard switch off
1W maximum
2W maximum
2W maximum
120 VAC
240 VAC
240 VAC
Dark
* Meeting VESA DPMS requirements measured from AC Input end of AC power cord.