Planar lc640.480.21-065 产品用户手册

下载
页码 40
LC640.480.21-065 Operations Manual (OM610-00)
15
Pixel Position
The position of pixel data, relative to the color filter orientation and scan direction
inputs is shown in Figure 7 below. Refer to Table 10 to see the relations between the
scan direction and the viewing direction.
Table 10. Display Positions.
Normal scan: DPS = “L” or “OPEN”
D (0,0)
D (1,0)
D (X,0)
D (638,0)
D (639,0)
D (0,1)
D (1,1)
D (X,1)
D (638,1)
D (639,1)
(D 0,Y)
D (1,Y)
D (X,Y)
D (638,Y)
D (639,Y)
D (0,478)
D (1,478)
D (X,478)
D (638,478) D (639,478)
D (0,479)
D (1,479)
D (X,479)
D (638,479) D (639,479)
Reverse scan: DPS = “H”
D (639,479)
D (638,479)
D (X,479)
D (1,479)
D (0,479)
D (639,478)
D (638,478)
D (X,478)
D (1,478)
D (0,478)
D (639,Y)
D (638,Y)
D (X,Y)
D (1,Y)
(D 0,Y)
D (639,1)
D (638,1)
D (X,1)
D (1,1)
D (0,1)
D (639,0)
D (638,0)
D (X,0)
D (1,0)
D (0,0)
Figure 7. Pixel Position of Input Data.
D (0,0)
D (639,0)
D (0,479)
D (639,479)
D (0,0)
D (639,0)
D (0,479)
D (639,479)
J3
J1
J1
J3
Normal Scan
Reverse Scan