Gas and Electrical Connection
GAS  CONNECTION
Verify  the  type  of  gas  supply  to  be  used,
either  natural  or  LP,  and  make  sure  the
marking  on  the  grill  rating  plate  agrees  with
that  of  the  supply.  Never  connect  an
unregulated  gas  line  to  the  appliance.  An
installer  supplied  gas  shut-off  valve  must  be
installed  in  an  easily  accessible  location.  All
installer supplied parts must conform tolocal
codes, or in the absence of local codes, with
the  National  Electrical  Code,  ANSI/NFPA  70
and  the  National  Fuel  Code,  ANSI  Z223.1. 
In Canada: Installation must be in accordance
with  the  current  CSA-B149.1,  Natural  Gas
Installation  Code  or  CSA-B149.2,  Propane
Installation Code and/or local codes. All pipe
sealants  must  be  an  approved  type  and
resistant to the actions of LP gas. Never use
pipe  sealant  on  flare  fittings.  All  gas
connections should be made by a competent
technician and in accordance with local codes
and  or  ordinances.  In  the  absence  of  codes,
the installation must comply with the National
Fuel Gas Code ANSI Z223.1. The gas grill and
its  individual  shut-off  valve  must  be
disconnected  from  the  gas  supply  piping
system  during  any  pressure  testing  of  that
system at test pressures in excess of 1/2 PSIG
(3.5 kPa). The gas grill must be isolated from
the  gas  supply  piping  system  by  closing  its
individual  manual  shut-off  valve  during  any
pressure  testing  of  that  system  at  test
pressures  equal  to  or  less  than  1/2  psi  (3.5
kPa).  Built-in  installations  must  be  plumbed
using a fixed/hard line if the unit is going to
be  operated  at  a  distance  exceeding  3  feet
(0.91  meters)  from  the  fuel  supply  per  ANSI
Z21.24 CSA.
GAS  CONVERSION 
To convert a grill from natural to
LP/Propane or LP/Propane to natural, you
MUST use conversion kit sold seperately.
ELECTRICAL CONNECTION
22
WARNING
DANGER
CAUTION
FOR YOUR SAFETY
Conversions should only be performed by an
authorized service technician.
WARNING
ELECTRICAL SHOCK HAZARD
This appliance is equipped with a 3’
(91.4 cm) 3-prong power cord with a
grounding plug for your protection
against shock hazard and should be
plugged directly into a properly grounded
receptacle. Do not cut or remove the grounding
prong from this plug. This unit is not fused and
installer must install a GFI. Unit must be
grounded in accordance with local codes or with
the National Electrical Code ANSI/NFPA 70, or
the Canadian Electrical Code, CSA C22.1.
Ventilation for Built-In Installations
1. At least one ventilation opening shall be provided on the exposed, exterior side of the 
enclosure located within 5 inches (127 mm) of the top of the enclosure and unobstructed.
The opening(s) shall have a total free area of not less than 1 in
2
/lb. (14.2 cm
2
/kg) of stored
fuel capacity.
2. At least one ventilation opening shall be provided on the exposed, exterior side of the
enclosure 1 inch (25.4 mm) or less from the floor level and shall have a total free area of not
less than 1/2 in
2
/lb. (7.1 cm
2
/kg) of stored fuel capacity. The upper edge shall be no more
than 5 inches (127 mm) above the floor level.
3. Every opening shall have a minimum dimension so as to permit the entrance of a 1/8 inch
(3.2 mm) rod. 
21
Vents
Not less than
5.00 inches
from inside
bottom of
countertop.
Not less than
1.00 inch from
inside floor of
installation.
1.00 inch maximum
5.00 inch
maximum
No more than 5.00 inches above
the floor of the installation.
5.00 inch
maximum