6
Do not attempt to repair the cylinder valve if it should
become damaged. The cylinder must be replaced.
7
2
8
1
Call an authorized gas 
appliance service technician 
or LP/Propane gas dealer.
  
Do not use the grill until 
the leak is corrected. 
OF
F
1
2
9
Stop a leak by tightening the loose joint or by
replacing the faulty part with a replacement part
recommended by the manufacturer.
If you are unable to stop a leak, shut off the gas 
at the cylinder valve. Remove the cylinder 
from the grill.
After checking for leaks, push in and turn any control
knob to release the pressure in the hose and manifold.
Turn off the control knob. 
Bubbling bubbles in the soap solution indicates that a
leak is present. 
27
1
OF
F
2
Check that all control knobs are in the “OFF” position. 
3
4
Apply the soap solution to fittings.
Turn cylinder valve knob counter clockwise one 
turn to open. 
Leak Testing
Although all gas connections on the grill are
leak tested at the factory prior to shipment,
a complete gas tightness check must be
performed at the installation due to possible
mishandling in shipment or excessive
pressure unknowingly being applied to the
unit. Periodically check the whole system for
leaks, or immediately check if the smell of
gas is detected. 
• Do not smoke while leak testing.  
• Extinguish all flames.
• Never leak test with an open flame 
WARNING
DANGER
CAUTION
FOR YOUR SAFETY
Before placing into operation, always check for
gas leaks with a soapy water solution. DO NOT
USE AN OPEN FLAME TO CHECK FOR LEAKS.
Make a soap solution of one part liquid detergent and
one part water. You will need a spray bottle, brush or
towel to apply the solution to the fittings. 
Note: For LP/Propane units, check with a full cylinder.