Viking Range vgrt242t 安装指导

下载
页码 13
GAS CONNECTION
Verify the type of gas supply to be used, either natural or LP, and make sure the marking on the rating plate agrees
with that of the supply.  Never connect an unregulated gas line to the appliance.  An installer supplied gas shut-off
valve must be installed in an easily accessible location.  All installer supplied parts must conform to local codes, or in
the absence of local codes, with the National electrical Code, ANSI/NFPA 70 and the National Fuel Code, ANSI
Z223.1.  In Canada:  Installation must be in accordance with the current CAN/CGA-B149.1, Natural Gas Installation
Code or CAN/CGA-B149.2, Propane Installation Code and/or local codes.  All pipe sealants must be an approved type
and resistant to the actions of LP gas.  Never use pipe sealant on flare fittings.  All gas connections should be made by
a competent technician and in accordance with local codes and or ordinances.  In the absence of codes, the installation
must comply with the National Fuel Gas Code ANSI Z223.1.  
The gas side burner and its individual shut-off valve must be disconnected from the gas supply piping system during
any pressure testing of that system at test pressures in excess of 1/2 PSIG (3.5 kPa).  The unit must be isolated from the
gas supply piping system by closing its individual manual shut-off valve during any pressure testing of that sysptem at
test pressures equal to or les than 1/2 psi (3.5 kPa).
Built-in installations must be plumbed using a fixed/hard line if the unit is going to be operated at a
distance exceeding 3 feet (0.91 meters) from the fuel supply per ANSI Z21.24.
2
GENERAL INFORMATION
1.         
WARNING: 
This outdoor gas side burner is not intended to be installed in or on recreational vehicles
and/or boats.
2.  
WARNING
Keep electrical supply cord and the fuel supply hose away from heated surfaces. 
3.  Keep area clear and free from combustible materials, gasoline, and other flammable vapors.
4.  When the outdoor gas side burner is not in use, the gas supply must be turned off at the LP gas supply cylinder.
5.  The pressure regulator and hose assembly supplied with the unit must be used.  Replacement pressure regulators
and hose assemblies must be those specified by the manufacturer.
6.  Finding a leak is not a “do-it-yourself” procedure.  Some leaks can only be found with the burner control in the on
position and this must be done by a qualified technician.
7.  The LP supply cylinder to be used must be constructed and marked in accordance with the specifications for LP-gas
cylinders of the U.S. Department of Transportation (DOT) or the National Standard of Canada, CAN/CSA-B339,
Cylinders, Spheres, and Tubes for the Transportation of Dangerous Goods.
8.  Gas Manifold Pressure - 
Natural gas - 4.0” W.C.P.
LP/Propane - 10.0” W.C.P.
9.  If the following instructions are not followed exactly, a fire causing death or serious injury may occur:
-Do not store a spare LP gas cylinder under or near this appliance.
-Never fill the cylinder beyond 80 percent full.
BASIC SPECIFICATIONS
Description
                    
VGSB152T                                             VGRT244T      
Overall Width                               15-5/16”  (38.9 cm)                               26 1/4” (66.7 cm)                                               
Overall Depth                                               To end of landing ledge      31-9/16”  (80.2 cm)
                                                                        To end of knobs                    32-5/8” (82.9 cm)
Overall Height                                               To cooking surface               10 1/2” (26.3 cm)
Cutout Width                                14 ” (35.6 cm)                                        24 3/4” (62.9 cm)
Cutout Depth                               27-1/2” (69.9 cm)                                  27-1/2” (69.9 cm)
Cutout Height                               10-1/4” (26.0 cm)                                  10-1/4” (26.0 cm)
Gas                                                 Natural:            standard residential 1/2” (1.3 cm) ID gas service line.
Requirements                                LP/Propane:     equipped with high capacity hose/regulator assembly for connection
to standard 5gal, 20 lb. LP/Propane gas cylinder with Type 1, QCC-1
connection or standard residential 1/2” (1.3 cm) ID gas service line.
Side Burner                         (2) - 15,000 BTU Nat./13,500 BTU LP       (4) - 15,000 BTU Nat./13,500 BTU LP             
Rating                                             (4.4 kW Nat./4.0 kW LP)                            (4.4 kW Nat./4.0 kW LP)                           
Approximate Shipping Wt.                         80 lbs. (36.3 kg)                     160 lbs (72.0 kg)