Vinotemp 100wc 用户指南
10
1) Display
During normal working conditions, the display shows the value measured by the
air regulation probe or the second probe (parameter /4). In case of active alarm,
the temperature flashes alternately to the code alarm.
2) Alarm Code Description
E0: fault air regulation probe
E1: evaporator product/food probe fault digital input alarm
IA: immediate external alarm (A4 and A7 parameters)
LO: low temperature alarm (AL, Ad and A0 parameters)
HI: high temperature alarm (AH, Ad and A0 parameters)
EE: data acquisition failure (see the manual for the default procedure)
Ed: timeout-ended defrost (dt, dP and r3 parameters)
dF: defrost in progress
3) Operating Indications on the Display
LED 1 or LED Button 5 indicates compressor ON;
LED 3 or LED Button 7 indicates defrosting ON;
LED 2 or LED Button 6 indicates presence of alarms.
* The blinking indicates that controller is waiting for a time delay to expire.
4) Set-Point (desired temperature value)
Press the SET button 6 for one second to display the Set-Point value;
After few seconds, the set value blinks;
Press UP button 5 or DOWN button 7 to increase or decrease the set-point
value;
Press the SET button 6 once more to confirm the new value.
5) Manual Defrost
Besides the automatic defrost, it is possible to activate a manual defrost by
pressing the button 7 for more than 5 seconds (it occurs only in the appropriate
temperature conditions).