页码 11
- 4 -
Figure 4
Twist and 
Secure
FOR OPTIONAL PENDANT MOUNT
1.  This unit includes a 1 1/2" NPT housing for a standard 1 1/2" 
     NPT pipe.  The RH7C can be used with other brackets  
     designed with 1 1/2" male pipe threads, such as the Videolarm 
     WM20G and WM20 wall mount brackets.
2.  Attach the housing coupling (Figure 3).
     NOTE:  Pipe threads should be clean and rust free. Use a sealer 
(such as Teflon™ tape or silicone sealer) on the threads.
Wiring Color Code for Power
1
Camera Power (24 VAC)
Red
2
Camera Power (24 VAC)
Orange
3
Accessory Power (24 VAC)
Yellow
4
Accessory Power (24 VAC)
Green
POWER
4.  Attach the wires from the wall to the connector provided, using the  
     wiring color code chart as a guide. 
5.  Once all wiring connections are made, place the wires inside the 
     wall mount bracket and close the access door.  Secure with the 
     screw removed earlier.
6.  Clean the outside of the dome. 
Figure 2
Conduit Entrance
3.  Open the access door on the bottom of the wall mount by 
     loosening the screw nearest the mounting plate (Figure 2).
Figure 3
Add thread 
sealing tape
1.  Mount the housing assembly to the mounting bracket and  
     housing coupling.  A safety cable is included with the housing to
     temporarily hold it while making wiring connections.
2.  Clean the outside of the dome.