Videolarm qsdpc2-70na5 用户指南

下载
页码 11
- -
AC Voltmeter
Camera
Monitor
Bridge Tap
NV-213
A
NV-213
A
NVT TROUBLESHOOTING
If you are experiencing problems, attempt to simplify your setup. Test 
each  cable  segment  separately.  For  example,  test  the  camera  and 
monitor together without the other equipment. Then add in the NVT 
transceivers,  back-to-back.  Test  each  segment  of  a  long  cable-run 
independently. Attempt to isolate the problem.
Below are problems that may be encountered. If the suggestions below 
are not helpful, or the recommendations are not effective, please call 
NVT’s customer support. NVT customer support can be reached 8:00 
AM to 5:30 PM PST at (800) 959-9870 or at (+1) (650) 562-0600.
FAINT OR BLURRY PICTURE; LITTLE OR NO COLOR
Possible causes include:
1.  Shielded  twisted-pair  cable.  Verify  that  the  wire  is  unshielded 
twisted-pair cable. Multi-pair cable with an overall shield is OK.
2. Longer wire distance than expected. Be sure to include any coax 
cable  that’s  part  of  this  distance.  Verify  end-to-end  connectivity 
with  an  ohm  meter.  Measure  the  distance  by  disconnecting  the 
transceivers,  shorting  the  far  end,  reading  the  loop’s  resistance 
at  the  near  end.  See  above  for  ohm  vs.  distance  ratings.  If 
necessary, replace transceivers with correct models specified for 
this distance.
3. Incorrect  distance  equalization  setting.  Adjust  the  equalization 
controls) with a mini screwdriver (NV-652R, NV-862R or the NV-
1662R). If the transmitter is an NV-653T, verify correct equalization 
switch setting.
4. Poor connection at a punch-block, splice, or coax cable. Re-check 
using the method described in #2 above, or use a wire test set.
5. Short between conductors of the twisted-pair. Use an ohm meter 
to locate the short.
6. Transient protection devices employing metal-oxide varistors. Use 
carbon blocks, gas-discharge tubes, or NVT transceivers w
i
th built-
in protection.
7. Check the camera. Are the focus and iris set correctly? Verify with 
portable monitor.
EXTREMELY FAINT PICTURE 
Only  faint  shadows  of  the  original  picture  are  visible.  One  of  the 
twisted  pair  conductors  is  open  or  the  wires  are  shorted  together. 
Check with an ohm meter.
OVER-SATURATED COLORS; HIGH CONTRAST GRAINY 
PICTURE; TOO BRIGHT, TORN PICTURE
Adjust the distance equalization as necessary. Verify that the monitor 
has a 75 termination, not in “loop-through”.
WON'T SYNC; WIDE, WHITE JAGGED AREAS
Looks like a scrambled Cable TV signal. Check polarity.
WON'T SYNC; TORN PICTURE
1. Make sure that you are using unshielded twisted pair wire. 
2. Check distance equalization settings. 
3. For  installations  with  passive  (non-amplified)  transceivers  at  both 
ends,  check  for  ground  loops.  This  may  be  done  with  an  AC 
Voltmeter, as shown below:
  If  the  voltage  is  greater  than  1/2  volt,  use  an  amplified  receiver, 
such as the NV-652R, NV-862R, or NV-1662R.
  Alternately, remove the ground at one end (usually at the camera 
end). Be sure that floating the camera conforms to local/regional 
and National Electrical Codes. 
4. Check for crosstalk from a second video path. Disconnect all other 
video sources. If the problem goes away, check for a split-pair or 
un-twisted wire.
FAINT STRIPES GLIDING UP OR DOWN THE SCREEN
These  are  caused  by  crosstalk  from  a  second  video  path,  or  with 
ground-loops in installations employing passive models at both ends. 
1. To  identify,  disconnect  all  other  video  signals  temporarily.  If  the 
interference goes away, check the wire to make sure the signal is 
traveling through a twisted pair. Is two-way video being sent more 
than  1,000  ft  (300m)  over  Category  2  or  3  wire?  If  so,  the  send 
and receive signals may need to go in separate jacketed cables, 
or upgrade to Category 5 wire.
2. Next, check for ground loops. See #3 above.
NO POWER LIGHT ON THE NVT UNIT
Check the blue “power” LED on powered NVT units. If the light is not 
on, the receiver is not getting power. Re-check the power source and 
connections. 
If the green LED is on but the power LED is off, check that the power 
supply is floating. Grounding one side of the power input may cause 
this condition.
NO GREEN LIGHT, NO VIDEO
The  NV-652R,  NV-862R  or  NV-1662R  series  receiver/hub  is  not 
detecting a video signal. There is an open or shorted connection. Use 
a multimeter to locate the fault. 
GHOSTS
Faint  shadows  of  the  original  signal  shifted  to  the  right.  This  is 
caused  by  an  impedance  mismatch  along  the  wire.  Verify  that  the 
monitor is terminated with 75 (not in “loop-through”.) Check that all 
wire is unshielded twisted pair. The high-frequency wire impedance 
should be 100. Check for bridge-taps (see below) either by inspecting 
wiring  closet  connections,  or,  if  available,  using  a  “Time-Domain 
Reflectometer” (T.D.R.), sometimes called a “cable tester”.
If the faint shadows are not copies of the original picture, but from the 
picture of some other camera, check for crosstalk:
Is any portion of the wire un-twisted?
Are the signals from two cameras split between two pairs?
Is there a short between a conductor of one signal and a conductor 
of another?