GE tfx26ppd 用户手册

下载
页码 88
Customer Service
Troubleshooting T
ips
Operating Instructions
Safety Instructions
Installation Instructions
7
When Your Refrigerator Is First Plugged In
How the Monitor and Diagnostic System Works
All panel lights come on for five seconds, 
a beep sounds, and lights go off except as
follows:
PF flashes in the display. Touch SYSTEM
CHECK-RESET 
to erase it.
NORMAL glows.
WARM TEMP glows until the refrigerator
cools down. It goes off when proper food-
keeping temperature is reached.
Door alarm beeper is activated and DOOR
ALARM 
glows.
CRUSHED ICE glows.
DOOR OPEN flashes if either door is open,
goes out when doors are shut.
Night light in ice and water dispenser 
is off.
How to Set the Door Alarm
To set the alarm press DOOR ALARM until it
glows.
The control beeps if either door is open for
more than 30 seconds.
The light goes out and the beeping stops
when you close the door.
DOOR ALARM
ON/OFF
Why the WARM TEMP Light Glows
At first, it’s probably because your newly-
installed refrigerator hasn’t completely
cooled down yet. Wait a few hours for it to
cool, and then the light will go out.
From then on, WARM TEMP will glow when-
ever temperatures inside get too high for
proper food storage. If this happens, open
the doors only when absolutely necessary,
and close them as quickly as possible.
As soon as inside temperatures return to
normal, the light goes out.
If WARM TEMP reappears and stays on for
longer than 4 hours, call for service.
WARM
TEMP
The diagnostic code flashes and the control
beeps when something starts to go wrong.
If more than one coded function requires
attention at the same time, the one with the
highest priority will be displayed first.
Pressing SYSTEM CHECK-RESET will erase
two codes immediately—PF and CI. The dE
and FF codes can only be erased by pressing
SYSTEM CHECK-RESET after the condition
that caused the code to flash has been cor-
rected.
SYSTEM CHECK-RESET will also evaluate 
all other coded functions. If NORMAL is 
lit during the displaying of a code, that func-
tion is operating properly.
SYSTEM
CHECK
RESET