OPERATION
OPERATION
Electronic Temperature Control
Operation:
The electronic temperature control constantly monitors box 
temperature as well as evaporator coil temperature to maintain 
consistent product temperatures.  The control also sends 
temperature readings to the digital temperature display.  The 
control circuits continually self-check and if an error occurs, 
the digital display will switch from temperature read-out to 
error read-out, i.e. E 1.  Even when an error is displayed, the 
refrigeration and controls system should continue to function, 
however not at optimal performance.  Whenever the display 
has an error read-out, Delfield Service should be contacted. 
At initial start-up or anytime power is disconnected, then 
reconnected to the unit, the control will delay all operations for 
a short time (up to 10 minutes.)  While in this delay period, 
the control initializes the control parameters and confirms 
that the temperature sensors and circuits are operational.  
The digital temperature display will not display temperature 
OR errors until the self-check is complete and the control 
has switched on the evaporator fan motor, compressor and 
condenser fan motor.
Refrigerator:
The control is located in the control box in the top of the 
refrigerator behind the removable louvered panel on the left 
side.  It is factory set at mid-range to maintain about 38˚F 
(3˚C) box temperature. To adjust for colder temperatures,
turn the knob clockwise.  For warmer temperatures, turn the 
knob counter-clockwise.  Turn the knob fully counter-clockwise 
to turn the refrigeration system off.  Never turn the knob more 
than 1 dial number and always allow 8 hours for temperature 
stabilization before making any additional adjustments.
 
Freezer:
The control is located in the control box in the top of the 
refrigerator behind the removable louvered panel on the left 
side.  It is factory set at mid-range to maintain about -3˚F 
(-18˚C) box temperature.  To adjust for colder temperatures, 
turn the knob clockwise.  For warmer temperatures, turn the 
knob counter-clockwise. Turn the knob fully counter-clockwise 
to turn the refrigeration system off.  Never turn the knob more 
than 1 dial number and always allow 8 hours for temperature 
stabilization before making any additional adjustments.
Energy Saver Switch
The energy saver switch is a rocker switch located next to 
the thermostat knob. The switch controls power to the frame 
heater to minimize condensation around the door opening.  
Press the switch to the “0” position to conserve energy.  If 
excessive condensation is observed on the door opening, 
press the switch to the “-” position, (red portion of the rocker 
will be visible).
Refrigeration & Defrost Cycle
Refrigerator:
Whenever the refrigerator is plugged in, and the control 
has completed initializing, the evaporator fans will run 
continuously and the digital temperature will display box 
temperature in degrees F.  The temperature control will cycle 
the compressor and condenser fan motor to maintain box 
temperature at the control setting.
  
Refrigerator Defrost
The temperature control also monitors the evaporator 
temperature and will turn off the compressor and condenser 
fan motor when needed to allow accumulated frost on the 
evaporator to clear.  During this defrost cycle, the digital 
temperature display will read dEF.  After the defrost cycle is 
complete, the temperature control will return to a normal 
cooling cycle, but the display will continue to read dEF until 
the evaporator returns to normal cooling temperatures  (up to 
30 minutes).
Freezer:
Whenever the freezer is plugged in, and the control 
has completed initializing, the evaporator fans will run 
continuously. After evaporator coil has reached operational 
temperature, the digital temperature will display box 
temperature in degrees F.  The temperature control will cycle 
the compressor and condenser fan motor to maintain box 
temperature at the control setting.
 
Freezer Defrost
The control also monitors compressor total running time 
and will enter a defrost cycle after total compressor running 
time is greater than 4-hours since the last defrost cycle OR 
if evaporator coil temperature drops below -34˚F (indicating 
excessive frost on the coil).
When the control enters the defrost mode, it switches OFF the 
evaporator fan motor, compressor, and condenser fan motor, 
and switches ON the defrost heater to warm the evaporator 
coil thereby melting all frost accumulated during the previous 
refrigeration  cycle.  The digital temperature display will now 
read dEF.  The control will continue the defrost cycle for a 
MINIMUM of 8 minutes and a MAXIMUM of 30 minutes 
depending on the amount of frost accumulated on the 
evaporator coil.
After the defrost cycle is complete, the control returns to a 
normal refrigeration cycle, however the evaporator fan motor 
will not switch on for 2 minutes AFTER the compressor and 
condenser fan motor have begun operating.  The digital 
temperature display will continue to read dEF until the 
evaporator has returned to normal freezing temperatures (up 
to 30 minutes).