Hitachi CP-X440 用户指南

下载
页码 49
47
Phenomena that may be easy to be mistaken for machine defects (continued)
Phenomenon
Cases not involving a machine defect
Reference
page
No pictures are 
displayed.
The lens cap is attached.
Remove the lens cap.
The signal cables are not correctly connected.
Correctly connect the connection cables.
The brightness is adjusted to an extremely low level.
Adjust BRIGHTNESS to a higher level using the menu 
function or the remote control.
The computer cannot detect the projector as a plug 
and play monitor.
Make sure that the computer can detect a plug and play 
monitor using another plug and play monitor.
Video screen
display freezes.
The FREEZE function is working.
Press the FREEZE button to restore the screen to normal.
Colors have a
faded- out
appearance, or
Color tone is 
poor.
Color settings are not correctly adjusted.
Perform picture adjustments by changing the COLOR 
TEMP, COLOR, TINT and/or COLOR SPACE settings, 
using the menu functions.
COLOR SPACE setting is not suitable.
Change the COLOR SPACE setting to AUTO, RGB, 
SMPTE240, REC709 or REC601. 
Pictures appear 
dark.
The brightness and/or contrast are adjusted to an 
extremely low level.
Adjust BRIGHTNESS and/or CONTRAST settings to a 
higher level using the menu function.
The WHISPER function is working.
Select NORMAL for the WHISPER item in the SETUP 
menu.
The lamp is approaching the end of its product 
lifetime.
Replace the lamp.
Pictures appear
blurry.
Either the focus and/or horizontal phase settings are 
not properly adjusted.
Adjust the focus using the focus ring, and/or H PHASE 
using the menu function.
The lens is dirty or misty.
Clean the lens referring to the section “Caring for 
ff the lens”.
Troubleshooting
NOTE  • Although bright spots or dark spots may appear on the screen, this 
is a unique characteristic of liquid crystal displays, and it does not constitute or 
imply a machine defect.