SNTP
The printer clock can be synchronized with an NTP server clock using the Simple Network Time Pro-
tocol (SNTP). To change the SNTP settings, use the “sntp” command.
tocol (SNTP). To change the SNTP settings, use the “sntp” command.
Limitation
❒
SNTP supports NTP servers running xnptd V3 and V4.
❖
❖
❖
❖ Reference
msh> sntp
❖
❖
❖
❖ NTP Server Address Configuration
You can specify the NTP server's IP address.
msh> sntp server IP_address
❖
❖
❖
❖ Interval Configuration
You can specify the interval at which the printer synchronizes with the operator-specified NTP serv-
er.
er.
msh> sntp interval polling_time
Note
❒
The factory default setting is 3,600 seconds.
❒
You can set the interval from 16 to 16,384 seconds.
❒
If you set 0, the printer synchronizes with the NTP server only when you turn the printer on. After
that, the printer does not synchronize with the NTP server.