Main points of Operation
Prevent Cool Air Blowing Off
In heating mode,the indoor fan will not run
immediately after the unit starts to prevent
the cool air blowing off.
Defrosting Function
In heating mode, when frost formed on the outdoor heat
exchanger, the air conditioner will automatically defrost a
few minutes. During defrosting, both indoor and outdoor
fan will stop running. When defrosting finished, air condi-
tioner will automatically back to running.
Hints
The air conditioner absorbs heat form outside and
releases inside when in heating mode, therefore the
outside environmental temperature will affect heating
effects.
Power Failure Compensation(to be applied for a necessary situation):
After the power failure compensation is set, if power failure suddenly occurs while the air
conditioner is working,it will resume the previous working state when the power is supplied
again.
Setting Method: When the remote controller is on (excluding timer mode and fan mode),press
                          the ìsleepî button on the remote controller 10 times within 5 seconds,and
                          after the buzzer rings 4 times, the air conditioner will enter the state of power
                          failure compenstation.
Cancel Method:Press the ìsleepî button on the remote controller 10 times within 5 seconds,
                         and after the buzzer rings 2 times, the power failure compensation mode will be
                         cancelled.
Note: When a power failure suddenly occurs during the air conditioner is working after the
         power failure compensation is set,if the air conditioner will not be used for a long
         time, please cut off the power supply to prevent its operation from being resumed
           after the power is supplied again, or press the ì Switch On/Off î button after the power
          comes again.
Defrosting Running
Wait a
minute
17
The followings are not malfuncition
Hua
Hua
Trouble Shooting
Water flowing sound is heard
When the air conditoner is started, when the
compressor starts or stops during operation
or when the air conditioner is stopped,it som-
etimes sounds ì Bi- Bi-î or ìGodo-Godoî. It is
the flowing sound of the refrigerant , not a
malfunction.
Cracking sound is heard
It smells.
This is caused by heat expansion or contra-
ction of plastics
Air blown out from the indoor unit sometimes
smells. The smell results from smells of
furniture, paint , tobacco absorbed by indoor
unit.
During operation, white fog comes out of
indoor unit.
When in COOL or DRY mode, a thin water
fog can be seen blown out of unit ,this is the
condensed fog because the suddenly cooled
indoor air is blown out.
Automatically switch into FAN mode during
cooling.
To prevent frost from being accumulated on the
indoor unit heat exchanger, it sometimes auto-
matically switched into the FAN mode,but it will
soon back to the cooling mode.
The air conditioner cannot be restarted soon
after it stops.
Air conditioner does not start?
This is because of the self-protection function
of the system, therefore,it cannot be restarted
for about three minutes after it stops.
Please wait for
three minutes
In function of code B ,set and cancel Auto restart function by using of "SWING" button.
Note:
Series remote controller units please press the remote controller botton "CODE" to choose the program of code "B"