Electric wiring
Note:
Electric wiring must be done by qualified person.
Use copper wire only, the parameter of connecting cable is H07RN-F 4G 0.75mm
2
.
Wiring of indoor unit
Insert the cable from outside the wall hole where piping already exist.
Pull it out from front.
Loosen terminal screws and insert cable end fully into terminal block, then tighten it.
Pull the cable gently to make sure it is tight.
Replace cover after wiring.
Wiring of outdoor unit
Insert the cable from inside the wall  hole
where piping already exists.
Pull it out from front.
Loose terminal screw and insert cable end fully
into terminal block, then tighten it.
Pull the cable gently to make sure it is tight.
Replace cover after wiring.
The power cable should be over 3G5.0mm
2
.
Installation procedures
The power supply connects from the outdoor unit.
OK
NO
terminal block
table clamp
Note:
When connecting indoor and outdoor wire, check the number on indoor and outdoor
terminal blocks.Incorrect wiring may damage air conditioner's controller or cause
operation failure.
The connecting cable and power cable are self-provided.
1 2 3
Y/G
1 2 3
POWER SUPPLY
L N
1PH,220V~,60Hz
HPU-36C13,HPU-44C13,HPU-36H13,HPU-44H13